• Tighten the gun to the cup securely with the nut and fitting supplied.
• Be sure to have the proper air pres s ure at the gun to operate. Proper air pres s ure for this tool should not exceed 50 PSI.
• Adjust fluid control screw and spray width adjustment screw to your desired pattern before using on pro d uc t ion.
• Clean all parts after use.
Fluid needle packing and nut
In normal use, the nozzle wings are
hor i z on t al as shown here. This pro v ides a
ver t i c al fan-shaped pat t ern which gives
max i m um, even ma t e r i a l coverage as the gun
is moved back and forth par a l l el to the sur f ace
being fin i shed.
776-3703
776-3703_Manual_091310.indd 4
FOR BEST PERFORMANCE, PLEASE BE SURE TO DO
THE FOL LOW ING BEFORE USING THIS TOOL
AdjusTmENTs
sprAyiNg
Spray pattern may be in f i n ite l y adjusted
from round to flat.
Trigger pivot
Spray width adjustment screw
Turn right for round, left for fan.
Fluid control screw
Turn right to decrease flow,
left to increase.
Air valve
Set inlet pressure at no more than 50 PSI. For op t i m um
per f or m ance, some ma t e r i a ls may spray better at PSI
ratings below 50 PSI. If unsure, always test at PSI ratings before
using on final production. Try spray. If it is too fine, de c rease the air
pres s ure or open fluid control screw. If the spray is too thick, close
the fluid control screw. Reg u l ate the pat t ern width and repeat
ad j ust m ent of spray as needed.