INTRODUCTION
The SKIT switch-type, weatherproof sensor adapter provides a quick,
reliable way to connect a compatible rain, freeze, moisture or other
normally closed switch-type sensors. The connection can be made
either directly to the LEIT series irrigation controllers or to one of the
micro-powered solenoid actuators.
FEATURES:
• Waterproof construction
• Easy to install
• Adapts to a wide range of sensors
SPECIFICATIONS:
• Compatible with normally closed switch-type sensors only
• Includes four 12-inch 14-gauge wire leads
• Length: approx 1.25" (3.1 cm); Diameter: approx 0.75" (1.9 cm)
INSTALLATION
Normally closed switch-type sensors (such as a rain, moisture or
freeze sensors) can be installed on a LEIT Controller if there is an
unused station available. If a spare station does not exist, a sensor
can be installed at one of the valve locations by connecting a SKIT
8821-4 to any LEMA actuator. For either type of installation, a SKIT
8821-4 is required to connect a sensor to the system.
SENSOR CONNECTION TO UNUSED STATION
If there is an unused station on the LEIT controller, connect the
sensor directly to it using a SKIT 8821-4.
PROCEDURE:
Run a red (hot) wire from the unused station connector position on
the LEIT controller to the red (hot) wire on the SKIT 8821-4. Then run
a white (common) wire from the common connector station position
on the LEIT controller to the white (common) wire on the SKIT. Finally,
splice the two SKIT black wires to the sensor's two normally closed
(N/C) wires.
SENSOR CONNECTION IF STATION IS NOT AVAILABLE
If station is unavailable, or the controller is too far from the sensor,
connect the SKIT 8821-4 to LEMA actuators at a valve closest to
the desired sensor location. This method can be used to minimize
excessive wire runs.
PROCEDURE:
Choose a valve that is closest to the sensor location. On the installed
LEMA series actuator, splice the red (hot) wire to the SKIT's red (hot)
wire AND to the red (hot) field wire creating a 3-wire connection.
Next, splice the LEMA's white (common) wire to the SKIT's white
(common) and connect both onto the common field wire. Again, a
3-wire connection should have been created. Finally, splice the two
SKIT black wires to the sensor's two normally closed (N/C) wires.
NOTE: For use with LEIT 4000, X and XRC controllers only.
Do not use with LEIT-2 or LEIT-2ET systems.
LEIT COMPATIBLE SENSORS
RAIN SENSORS:
HUNTER MINI CLIK
RAIN BIRD RSD
MOISTURE SENSOR:
IRROMETER WEM-B
FREEZE SENSOR:
HUNTER FREEZE CLIK
RAIN/FREEZE COMBO SENSOR:
HUNTER RAIN-CLIK RFC
LEGEND:
1. Finish grade
2. 6" round valve box
3. SKIT adapter, part number 8821-4, use with each sensor
4. To controller or valve
5. (4) Dry splice waterproof connectors
6. Normally closed wire from sensor
7. Common wire from sensor