Interconnection details:
● Terminals marked 6(NA)-7(COM)-8(NC).
These are used in home automation applications and indicate the
unit's status. There are two:
○ STATUS OK: No incidents. Contacts 7-6 closed.
○ STATUS NOT OK: Contacts 7-8 closed. Activated whenever
there is an incident affecting the unit, such as lack of salt, lack
of flow or excess salt.
There is a delay in activation of this output, i.e. the contacts do
not change the moment the incident is detected to avoid false
alarms being sent to any external control equipment.
● Terminals marked 9(HAB)-10(AUX)-11(COM).
These are used to control the device and function as follows:
○TERMINALS 11-9: Responsible for enabling the unit. If the
factory-fitted jumper is removed, the unit will not start. This input
is normally used to latch with the filter pump auxiliary contact
or to disable the chlorinator via a home automation system
whenever chlorination is not required.
○TERMINALS 11-10: This is an input used to force the unit to
100% chlorine production. When these two terminals are active
the unit ignores the input from the display panel and produces
chlorine non-stop.