Dandy DER202W Manual Del Propietário página 10

Estufas electricas compactas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
3 WIRE POWER CORD INSTALLATION
The neutral or ground wire of the power cord must
be connected to the neutral terminal located in the
center of the terminal block. The power leads must
be connected to the lower left and the lower right
terminals of the terminal block.
1. Remove the three lower terminal screws from the
terminal block.
2. Insert the three terminal screws through each
power cord terminal ring and into the lower
terminals of the terminal block.
3. Be certain that the center wire is connected to
the center lower position of the terminal block.
4. Tighten screws securely into the terminal block.
5. Do not remove the ground strap connection.
1. Terminal block
2. Neutral terminal
3. Ground strap
4. Power cord
5. Ground plate
5
4
9
1
2
3

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Der202bDer202bss

Tabla de contenido