CONTENTS
These parts are included with your Flex Blower:
2 - blower mounting legs
1 - 6" wide blower panel
2 - 3" wide blower panels
1 - Parts Bag containing:
(4) wood screws #10 x .50
(4) blower mount brackets
(1) strain relief bushing
PLAN THE INSTALLATION
If you choose to mount the Flex Blower directly to the Downdraft
housing - refer to installation instructions in the Downdraft manual.
If you choose to mount the Flex Blower in a remote location,
(such as the cabinet back, cabinet side, or floor joists) - follow
the instructions below.
INSTALL FLEX BLOWER
IN REMOTE LOCATION
NOTE: THE FLEX BLOWER MUST BE INSTALLED WITHIN
4-FEET OF THE DOWNDRAFT'S ELECTRICAL PANEL.
The Electrical Panel can be mounted directly to the Downdraft
housing - or mounted in a remote location (always within 4-feet
of the Flex Blower).
INLET
(from downdraft)
1. Determine how the 8" round INLET and OUTLET ductwork
will connect to the Flex Blower.
For use when mounting Flex
Blower directly to Downdraft
housing. (See Downdraft
instruction manual.)
OUTLET
(to roof cap
or wall cap)
2. Remove the necessary 1/4-20 x .50 hex head screws and attach
4 MOUNTING BRACKETS to the Flex Blower - using 4 of the
6 POSSIBLE BRACKET MOUNTING LOCATIONS.
8-IN.
ROUND
DUCT
(from
downdraft)
3. Mount Flex Blower to back of cabinet, floor joist, or adequate
framework (constructed by installer) with appropriate
MOUNTING SCREWS (not included).
4. Connect 8" ROUND DUCT from Downdraft housing to Flex
Blower inlet and from Flex Blower outlet to roof or wall cap.
For best performance: Choose the ducting option which allows
the shortest length of ductwork and a minimum number of
elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
5. Use strain relief bushing (provided) to attach Flex Blower wiring
to wiring box on Downdraft's electrical panel and make wiring
connections. (See Downdraft manual for instructions.)
2
Model VDV
(4) MOUNTING
BRACKETS
attached with
1/4-20 X .50
HEX HEAD
SCREWS
(6) MOUNTING
BRACKET
LOCATIONS
MOUNTING SCREWS
(not included)
ROUND
(to roof cap
or wall cap)
I
600
8-IN.
DUCT