2. The heater should be located on a solid, level and non-corrodible structure that is
capable of supporting the weight of the heat pump. It must be fixed by bolts (M10) to
concrete foundation.
At least 300mm
At least 300mm
3. The heat pump should be far from any source of combustibles and corrosive material to
avoid any damage to this unit.
Never place heat pump near sprinkler systems, evaporation of acid or alkaline gas. If you live in an
oceanfront area, the heat pump should be placed out of direct spray of sand and salt, since this will also
clog, damage, and corrode the unit. You may consider protecting your heat pump by planting shrubbery
or a privacy fence between the unit and the prevailing beachfront wind.
4. When the machine is running, there will be condensation water discharged from the
bottom. Make sure there is enough space for water drainage.
TIPS:
HEAT PUMPS GENERATE WATER CONDENSATION DURING NORMAL OPERATION.
THIS SHOULD NOT BE MISTAKEN FOR A LEAK IN THE UNIT.
At least 300mm
At least 300mm
!!Warning:
Don't install the heat pump close to a wall or
plants. And Never inside a closed building!
!!Warning:
The machine must not be hung onto the
wall with soft pipe since the inlet/outlet
union on the machine can't hold weight.
The machine must always be connected
with hard pipe!