Idiomas disponibles

PC Transmit Data to MICOM
Command
1st
Set-Status(Normal)
0 x 61
Set-Status(Digital)
0 x 62
Message-Status
0 x 64
Iris-Status
0 x 65
Red-Status
0 x 67
Blue-Status
0 x 68
Zoom-Status
0 x 69
Focus-Status
0 x 6A
(1)
Focus-Status(Max)
0 x 6B
(1)
Focus-Status(Min)
[Note 1] This command returns focus maximum/minimum data at current zoom position.
6
RS232C Command Code (UF-80)
2nd
3rd
4th
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 00
0 x 05
0 x 00
0 x 00
0 x 0A
0 x 00
PC Receive Data from MICOM
1st
2nd
3rd
0 x 61
"ACK data" Status(MSB) Status(LSB)
0 x 62
"ACK data" Status(MSB) Status(LSB)
0 x 64
"ACK data" Status(MSB) Status(LSB)
0 x 65
"ACK data"
0 x 00
0 x 67
"ACK data"
0 x 00
0 x 68
"ACK data"
0 x 00
0 x 69
"ACK data" Status(MSB) Status(LSB) Range:"0~1904"
0 x 6A
"ACK data" Status(MSB) Status(LSB) Range:"0~2225"
"ACK data" Status(MSB) Status(LSB) Range:"648~2225"
0 x 6B
"ACK data" Status(MSB) Status(LSB) Range:"0~1383"
Remark
4th
Bit definition
of Status
represents
Page 5, 6, 7
Status
Range:"1~120"
Status
Range:"1~200"
Status
Range:"1~200"