LP/PROPANE GAS CONVERSION
This appliance can be used with Natural Gas or LP/Propane gas. It is shipped
from the factory for use with natural gas. A kit for converting to LP gas can be
purchased separately from www.cosmoappliances.com.
When the cooktop is converted for liquid petroleum (LP) gas, the LP gas supply is
required to provide a minimum of 10" to a maximum of 14" water column to the
cooktop regulator.
The conversion must be performed by a qualified service technician in accordance
with the kit instructions and all local codes and requirements. Failure to follow
instructions could result in serious injury or property damage. The qualified agency
performing this work assumes responsibility for the conversion.
24" Burner and Orifice Characteristic Table
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L
Triple
Front L
Semi-Rapid
Rear R
Broil burner
Top
Bake burner
Bottom
NOTE: The triple burner has only two injectors, one injector mounted in the center
and one mounted below the cover plate. To access the second injector, remove the
two screws and the cover plate.
a
Opening in grate for wok ring (provided) is located over left front burner.
Orifice
Diam. (mm) Type
1.10
0.70
1.29
0.80
0.99 x 5
0.56 x 5
1.29
0.80
1.4
0.85
1.7
1.0
a
Gas
Pressure
[i.w.c.]
NG
4"
LP (Propane)
10"
NG
4"
LP (Propane)
10"
NG
4"
LP (Propane)
10"
NG
4"
LP (Propane)
10"
NG
4"
LP (Propane)
10"
NG
4"
LP (Propane)
10"
a
Rate
[BTU/h]
5000
5000
6900
6500
17400
15000
6900
6500
7900
7900
10700
10800
23