CONNECTION
For the connection of your regulator we advise you to ask assistance of qualified personel in accordance to
the standards in your country.
Connect each component to the symbols added for this purpose (cables not included).
Please follow the connection order in accordance with the polarities.
In case of non-compliance, your solar charge controller as well as your battery may get damaged.
Connect your battery to the solar charge controller (+ and -)
The battery indicator light should turn on
Connect your solar panel to the charge regulator (+ and -)
Select your battery's technology:
- Press and hold the button for 5 seconds, the light should start blinking
- Select your battery's technology by pressing the button
Liquid:
Gel:
AGM:
-
To confirm your selection, wait for 5 seconds. The light will dtop blinking
and the Unimppt has memorised your last setup.
In case of disconnection, follow the opposite order
GROUNDING – INSTALLATION CLASS
The grounding of the solar charge controller is often not needed. If you do want to ground, always do this on
the negative pole of the battery.
If the open circuit voltage of your solar panels is higher than 75 V (throughout the complete operating
temperature range), the whole solar system must be installed according to the II class of protection.
28/52
Open lead/acid flooded battery
Gel battery
Lead battery (maintenance-free), AGM...
www.uniteck.fr