CARE AND MAINTENANCE
Signs of possible blockage include:
•
Gas odor with extreme yellow tipping of flame.
•
Heater does NOT reach the desired temperature.
•
Heater glow is excessively uneven.
•
Heater makes popping noises.
•
Spiders and insects can nest in burner or orifices. This dangerous condition can damage heater and render
it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may help clear
away smaller particles.
•
Carbon deposits may create a fire hazard. Clean dome and burner screen with warm soapy water if any
carbon deposits develop.
•
Battery check: Please ensure the battery is installed before use. Take out the battery if the unit will not be
used for a long time.
Note: In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal.
Frequently check for corroded areas and repair them promptly.
Storage
Between uses:
•
Turn off control valve and cylinder valve.
•
Disconnect the hose regulator from propane cylinder.
•
Remove the battery from the igniter.
•
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet,
hail, snow, dust and debris).
•
If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Note: Wait until heater is cool before covering.
During periods of extended inactivity or when transporting:
•
Turn off control valve and cylinder valve.
•
Disconnect the hose regulator and move the cylinder to a secure, well ventilated, outdoor location.
•
Remove the battery from the igniter.
•
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet,
hail, snow, dust and debris).
•
If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Never leave LP cylinder exposed to direct sunlight or excessive heat.
Note: wait until heater is cool before covering.
Service
Only a qualified service person should repair gas passages and associated components.
Caution: Always allow heater to cool before attempting service.
21