INDEX
1 Introduction to the instructions and warnings 4
2 Product description
3 Specifications
4 Installation
5 Testing
6 Maintenance
Disposal
8 Drawings and diagrams
1
Introduction to the instructions and warnings
IThis manual is intended only for qualified technical
personnel for installation.
No information contained in this document may be
considered of interest to the end user.
This manual refers to the AG/BLED lights for the
cap of the ROGER AGILIK barrier and should not be
used for different devices.
ELECTROCUTION
WARNINGS
Read the instructions carefully before installing.
To avoid the risk of electric shock and personal injury,
before working on the device, always disconnect the
power supply.
The installation should only be performed by
qualified personnel in accordance with current
legislation.
Implement connections with the cables provided,
according to the instructions of the manufacturer;
do not change or alter in any way the cables.
WARNING! LEDS ARE SENSITIVE TO
ELECTROSTATIC DISCHARGE, SO AVOID
TOUCHING THE SIDES OF THE BOARD.
3
Product description
POWER SUPPLY VOLTAGE
MAXIMUM INPUT POWER
OPERATION TEMPERATURE
PROTECTION RATING
PRODUCT SIZE
4
HAZARD
AG/BLED
Page
2
Specifications
4
LED lights for the cap of the ROGER AGILIK barrier
4
are intended to flashing (AG/BLED) to indicate the
5
movement of the automated unit.
5
By configuring the control unit (AG/CTRL) to which
5
they are connected, you can change the switching
5
on mode (parameter
in extended mode).
14
The electronic boards are equipped with LEDs of 3
types:
• MASTER (AG/BLED/M) equipped with 2 5-way
connectors for connection to the main unit
and/or to another MASTER. It also has a 2-way
connector to which it is COMPULSORY to connect
a SLAVE board.
• SLAVE (AG/BLED/S) equipped with a 2-way
connector for connection to the MASTER board.
• SINGOLA/MASTER (AG/BLED/U) performs the
same function but has a jumper that allows you
not to connect the SLAVE and not use the board
only. Figure 1, detail B shows the jumper to be
put in position 6 LEDs, in the case the SLAVE is
connected, or to be put in position 3 LEDs in the
event the SLAVE is NOT connected.
The AG/BLED is a kit that includes 4 light elements
(2 x AG/BLED/M e 2 x AG/BLED/S) including shells
and wiring to connect them to each other and to the
control unit.
The connection to the control unit consist of two
cables joined by a flying connector: this makes it
easier subsequent lifting operations of the cap to
access the control unit.
24Vdc ± 10%
6 W
-20°C ... +55°C
IP40
size in mm. 150x38x57 x4pcs Weight: 0,3Kg
-7
in simplified mode or