Electrical Connection - BRIO ZX30 Información Técnica

Iluminación subacuática mediante led
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
Technical instructions

5. Electrical connection

Installation of this product involves a hazard of electric shocks. We strongly recommend you
contract a professional installer. Incorrect installation places you in danger and may irre-
versibly damage the product and the equipment connected to it. In compliance with the NF C
15-100 standard, pool lights installed in Volume 0 must always be powered with SELV (Safety
Extra Low Voltage). Always cut off the power upstream before handling the electrical instal-
lation.
Risk of electric shock. Only connect to a circuit which is protected by a ground-fault circuit
interrupter. If you are not sure if these types of devices are fitted, contact a qualified electrician.
1. Place the o-ring in the dedicated housing of the bayonet plug (refer to picture). Before the assembly it
is required to lubricate the o-ring to ensure a proper tightening. (A)
2. Pass the cable through the cable gland of the bayonet plug.
3. connect the cable at the back of the light and check if the tightening is well done.(B) (Don't strip the cable
to ensure a good tightening in the cable gland)
4. Let the cable gland open and fix the bajonet plug onto the back of the light. Check if the o-ring is well
placed between the bajonet plug and the light (C). According to the tightening you may hear 2 or 3 clicks.
5. Tighten the cable gland (D) und check if the black cable sheath is clamped as well.
The cable to connect at the light is the one with the shortest stript part (2.5cm). The other part
(6cm stript part) is for the connection at the 12V AC power supply..
BRIO ZX30
v40ML
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pk10r007

Tabla de contenido