Dimensions; Installation Of The Unit - PSA ZODIAC Uranus+ Manual De Instalación Y De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35

2.2 Dimensions

+
UP
35-70
+
UP
120-240
Dimensions in mm

3. INSTALLATION OF THE UNIT

The heater shall be be placed in a technical equipment area (ventilated, dry and without stored pool
maintenance substances), close to the boiler and to the filter of the pool. It shall be fixed onto the floor,
making sure it can't be flooded when cleaning the technical facility with a nozzle.
In the event the boiler is away from the technical facility, install the exchanger close to the boiler in order
to reduce thermal losses on primary circuit. Connect to the circuit of the pool by means of Ø 50mm
pipes.
Notice: If the exchanger is far away from the boiler, provide the hydraulic connection with appropriate section
taking account of the distance, the flow rate and the pressure drop. In some cases, the circulating pump should be
replaced with a more powerful pump. In any case, these connections shall be properly insulated and fitted with
automatic air bleed on high points of the circuit.
139
62
250
342
3
GB
116
450

Publicidad

Tabla de contenido
loading

Tabla de contenido