Position the impeller (I) – g.2 in the motor (N) – g.3
Position the shaft (L) in the tting in the impeller cover (G) – g.4
Position the motor support (M) on the motor (N) as shown in – g.5
Connect all the above by inserting the shaft (L) in the impeller opening (I) – g.6.
Make sure the tting on the impeller cover (G) corresponds to the connection for the air intake tube on the air
intake chamber and click on (H) – g.7.
Click the connector (Q) on the pump chamber (F) – g.8-9
Connect the "Slimskim" pump chamber (F) to the impeller cover (G) – g.10
Motor assembly – g.11
Connect the black air tube (P) to the air intake chamber (H) – g.12
Fig.13 Insert the grid (U) in the slot at the bottom of the skimmer body.
Fig.14 Insert the separation for the intake chamber (B) in the slot closest to the front part of the skimmer (Hydor
logo) to a complete stop touching the grid.
Place the motor assembly in the horizontal slot on the skimmer body (A) make sure that the connector (Q)
correspond to the opening on the separation (B) – g.15
Apply the magnet (R)+ suction cups to the clips (S) on the back panel of the skimmer (C)
Insert the back panel (C) in the slot on the back part of the skimmer (A) to a complete stop – g.17
Place the o-ring (O) on the collection cup (E) of the skimmer. – g. 18-19
Position the small suction cups (S) on the back panel (C) – g.20
Position and block the air intake tube and the electrical cable on the suction cups (S) as in the image n.20.
Place the collection cup at max height (o-ring should be on the lowest position possible) and with this position
measure and cut the air tube (P) a few cm above the lid. Positioned the air control (T) on the lid and then connect
the air tube. – g. 21
Installation
The "Slimskim" is designed to be positioned inside the aquarium using the supplied magnet + suction-cup
supports (for glass/acrylic up to 10mm/3/4" thick). It' s adaptable and is the ideal solution for aquariums that do
not have a sump.
After assembling the product, please proceed as follows:
Choose where to position the skimmer inside the aquarium, remember to clean the surface (both inside and
outside the aquarium) carefully so the magnet+suction-cup support can stick properly.
Position the skimmer, as suggested n g. 22, so that the water level is at the mid-height of the grid to guarantee
adequate surface aspiration.
Position the collection cup adjusting the o-ring as suggested in g.23.
Connect the pump to the electrical supply.
The following instructions on regulating water level and air ow are only indicative for the start up of the skimmer.
It will then be up to the Fishkeeper to adjust the system to better t speci c needs (tank size, stocking, foam, etc).
IMPORTANT: the skimmer needs to run at least 3/7 days before it starts foaming properly and the
setting becomes nal. It is possible to notice some air bubbles that enter the aquarium through the
drainage, this is normal, and they will disappear once the skimmer reaches it' s operating balance.
Regulation
COLLECTION CUP REGULATION:
For aquariums with heavy stocking or for dark foam/skimate, lift the collection cup and lower the o-ring
gradually as shown in gure 23b
For aquariums with normal stocking or for light foam/skimate lower the collection cup by lifting the o-ring