Descargar Imprimir esta página

Monacor International TG-10CH18 Manual Del Usario página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

www.jts-europe.com
These instructions are intended for
ENGLISH
users without any specific technical
knowledge. Please read the instruc-
tions carefully prior to operation and
keep them for later reference.
1 Applications
The charging cases TG-10CH18 and TG-10CH36 are
used for recharging the lithium-ion batteries of the
transmitters and the receivers of the wireless TG-10
system:
– case TG-10CH18 to recharge the batteries of up to
18 units at the same time
– case TG-10CH36 to recharge the batteries of up to
36 units at the same time
To recharge the batteries, insert the transmitters / re-
ceivers in the charging compartments, connect the
case to a mains socket via its power supply unit and
activate the charging function. The design of the
charging compartments will ensure correct insertion
of the units and thus prevent inadvertent reverse
polarity. Protective circuits are provided to prevent
damage to the batteries, e. g. by overload.
The charging case is also suited for storage and
transport of the units inserted. To secure the case,
model TG-10CH36 offers two key locks and a com-
bination lock.
2 Safety Notes
The units (charging case and power supply unit) cor-
respond to all relevant directives of the EU and are
therefore marked with
.
WARNING The power supply unit uses danger-
ous mains voltage. Leave servicing to
skilled personnel only. Inexpert han-
dling may result in electric shock.
The units are suitable for indoor use only. Protect
them against dripping water and splash water,
high air humidity and heat (admissible ambient
temperature range 0 – 40 °C).
Do not place any vessel filled with liquid on the
units, e. g. a drinking glass.
The heat generated within the charging case must
be dissipated by air circulation. Therefore, do not
cover the air vents inside the case.
Do not operate the charging case and immediately
disconnect the power supply unit from the mains
socket
1. if the units or the mains cable are visibly
damaged,
2. if a defect might have occurred after a unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the units must be repaired by skilled
personnel.
Never pull the mains cable to disconnect the mains
plug from the socket, always seize the plug.
For cleaning only use a dry, soft cloth; never use
water or chemicals.
No guarantee claims for the units and no liabil-
ity for any resulting personal damage or material
Vertrieb von JTS-Produkten – Distribution of JTS products
damage will be accepted if the units are used for
other purposes than originally intended, if they are
not correctly operated, or if they are not repaired
in an expert way.
Important for U. K. Customers!
The wires in the mains lead of the power supply unit
are coloured in ac cord ance with the following code:
green / yellow = earth,
blue = neutral
brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
1. The wire which is coloured green and yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the earth
symbol
, or coloured green or green and yel-
low.
2. The wire which is coloured blue must be con-
nected to the terminal which is marked with the
letter N or coloured black.
3. The wire which is coloured brown must be con-
nected to the terminal which is marked with the
letter L or coloured red.
Warning – This appliance must be earthed.
If the units are to be put out of operation
definitively, take them to a local recycling
plant for a disposal which is not harmful
to the environment.
3 Storage and Transport
of  Transmitters / Receivers
To prevent damage to the charging case, do not
subject it to severe shocks during transport and do
not drop it.
3.1 Charging case TG-10CH18
Slide the two black latches on the handle outwards
in arrow direction and open the lid. Insert the trans-
mitters / receivers
and slide back the latches towards the handle.
3.2 Charging case TG-10CH36
Open the three snap locks of the lid: Press the light
grey handle on the snap lock and pull the handle so
that the lock will snap open. Insert the transmitters /
receivers
chapter 4, step 2.
Carefully close the lid and engage the snap
locks. There are two key locks on the sides and a
central combination lock (factory-set to "000").
To set the combination lock to your own combina-
tion, proceed as follows:
Model
Number of compartments
Charging time
Power supply
Dimensions
Weight
®
MONACOR INTERNATIONAL GmbH & Co. KG, Zum Falsch 36, 28307 Bremen, Germany
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
©
chapter 4, step 2. Close the lid
Specifications
TG-10CH18
up to approx. 8 hours (depending on battery status)
15 V (⎓) /3.3 A
via power supply unit provided
361 × 422 × 189 mm
3.6 kg
TG-10CH18
Order number 25.2660
TG-10CH36
Order number 25.2680
Charging Case for Receivers and
Transmitters of the System
1) Set the dials of the lock to the current combination
and open the snap lock.
2) On the back of the combination lock, push the
small metal lever to the right, then downwards
and engage it.
3) Set the new combination with the dials.
4) Disengage the metal lever so that it will return to
its initial position. The lock is now set to the new
combination.
5) Close the snap lock and set the combination lock
to a different combination to secure the case.
Via the telescopic handle, the case can be pulled
like a trolley: To extract / retract the handle, press the
light grey button to unlock it. A pocket for storing
accessories is provided on the lower side of the case.
4 Recharging the Batteries of the
Transmitters / Receivers
1) Open the case
chapter 3.1 or 3.2.
Attention: To avoid overheating, do not close
the case while charging!
2) Insert the transmitters / receivers, with their charg-
ing contacts facing downwards, in the charging
compartments. When inserting the units, push
them into the compartments to ensure a tight fit.
3) The case is supplied with a power supply unit
(with separate mains cable): For transport, it is
secured in the case with Velcro fastener. Connect
the power supply unit to the jack DC INPUT of the
case and via the mains cable to a mains socket
(230 V/ 50 Hz). The power LED on the power supply
unit will light up.
4) To activate the charging function, set the switch
to ON (switch illuminated).
5) As long as a charging compartment is empty, its
charging LED will keep flashing. While charging
the battery of a unit in a compartment, its charging
LED will light permanently.
6) When the battery of a unit has been fully re-
charged, the corresponding charging LED will be
extinguished. The unit may be removed from the
compartment.
7) To deactivate the charging function, set the switch
to OFF (switch no longer illuminated).
If the case is not used for charging, disconnect
the power supply unit from the mains socket; it
will have a low power consumption even when the
charging function has been deactivated.
Note: If a charging LED starts flashing while charging
is still in progress, the charging case performs a self-
test to protect the battery.
TG-10CH36
18
15 V (⎓) /6 A
via power supply unit provided
400 × 561 × 230 mm
Subject to technical modification.
A-1128.99.03.09.2017
36
7.3 kg

Publicidad