Best KEX8087 Manual Del Usuario página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WIRING
!
CAUTION: All electrical wiring should be
done by a qualified person (s) in accordance
with all applicable codes and standards.
This range hood must be properly grounded.
Do not turn power on at service panel until
all wires have been connected.
Blower connection at hood:
1. Run 2-wire plus ground power cable from
the exterior blower to the hood's wiring box
marked "motor connection". Fig. 7
2. Remove the cover from the wiring box and
remove one knockout. Fig. 7
3. Feed 6" of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector. Fig.7
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground. Fig.7
5. Replace the wiring box cover and screws.
make sure wires are not pinched between
the cover and box.
Exterior blower connection:
1. Make electrical connections at the exterior
blower (see instructions provided with the
exterior blower).
Power connection at hood:
1. Run 120 VAC electrical power cable to the
hood wiring box marked "120VAC input".
Fig. 8
2. Remove the cover from the wiring box and
remove one knockout. Fig. 8
3. Feed 6" of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector. Fig. 8
4. Make electrical connections at the hood.
Connect white-to-white, black-to-black
and green-to-ground. Fig. 8
5. Replace the wiring box cover and screws.
Make sure wires are not pinched between
the cover and box.
BLOWER CONNECTION AT HOOD
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
POWER CONNECTION AT HOOD
CONNECT:
WHITE-TO-WHITE,
BLACK-TO-BLACK,
GREEN-TO-GROUND.
- 11 -
Exterior blower
BOX MARKED
"MOTOR
CONNECTION"
FIG. 7
BOX MARKED "120
VAC INPUT"
120 Volt 60Hz
LINE-IN
FIG. 8

Publicidad

Tabla de contenido
loading

Tabla de contenido