3.2 Switching on the 30 Hz filter
3.3 Multitplying factor
3.4 Dividing factor
3.5 Decimal point
MN05401012E
30 Hz filter off (f max )
30 Hz filter on
It can be set from 00.0001
up to 99.9999.
"0" is not accepted!
It can be set from 00.0001
up to 99.9999.
"0" is not accepted!
The decimal point defines
the resolution.
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
www.comoso.com
3.6 Display mode
3.7 Max. time to wait until "0" is displayed
This parameter indicates how long it takes, when
measuring is active, until "0" is displayed.
3.8 End of programming
Value conversion and
display in 1/s
Value conversion and
display in 1/min
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
5