Operation - Factory Buys Direct FBDC80V Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Connect fuel gas fitting on hose/regulator
assembly to propane tank(s). Turn fuel
gas fitting counterclockwise into threads
on tank. Tighten firmly using a wrench.
IMPORTANT: Tighten regulator with
vent pointing down. Pointing vent down
protects regulator from weather damage.
3. Connect hose to the valve inlet. Tighten
firmly using a wrench. You must use the
regulator supplied with heater even if
propane tank has one.
4. Open propane supply valve on propane
tank(s) slowly. Note: If not opened slowly,
excess-flow check valve on propane tank
may stop gas flow. If this happens, you
may hear a click inside the regulator as-
sembly, this is the check valve closing. To
reset the excess flow check valve, close
propane supply valve and open again
slowly.
5. Check all connections for leaks. Apply
mixture of liquid soap and water to gas
joints. Bubbles forming show a leak that
must be corrected.
WARNING: Review and un-
derstand the warnings in Safety,
page 2. They are needed to safely
operate this heater. Follow all lo-
cal codes when using this heater.
80,000 BTU MODEL
TO START HEATER
1. Make sure unit is turned off by slightly
pressing and turning control knob fully
clockwise to OFF. Open propane supply
valve on propane tank(s) slowly.
2. Push and turn control knob counterclock-
wise to the LOW position. With the control
knob pushed in, press and release the
piezo ignitor button. Keep pressing piezo
ignitor button until the burner lights. Hold
control knob down for a maximum of
15 seconds while attempting ignition. If
heater does not ignite, release control
knob and wait 5 minutes before attempting
reignition.
6
INSTALLATION
Propane Supply
Valve
Propane
Tank

OPERATION

3. After ignition, hold control knob down for
4. When main burner remains lit, set heat-
5. If burner goes out, turn off gas. Slightly
Ignitor Button
www.factorybuysdirect.com
Figure 3 - Regulator Position
Hose
Figure 4 - Hose and Valve Inlet
approximately 30 seconds. This activates
the automatic control system.
er at the desired heat level by slightly
pressing the control knob and turning it
counterclockwise to the Medium or High
settings.
press and turn control knob fully clockwise
to OFF. Check fuel supply. If adequate
fuel is available, restart heater beginning
at step #1.
Control Knob
Figure 5 - 80,000 BTU Controls
Hose
Regulator
POL
Fitting
Valve Inlet
160945-02A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fbdc80v-cFbdc200vFbdc200v-c

Tabla de contenido