Technical Characteristics - CAME DBS01 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
DBS01 - DBS02
GB
"IMPORTANT INSTRUCTIONS FOR SAFE INSTALLATION"
WARNING: IMPROPER INSTALLATION MAY CAUSE SERIOUS
DAMAGE. FOLLOW ALL INSTALLATION INSTRUCTIONS.
THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTAL-
LERS OR QUALIFIED PERSONNEL
Legend
This symbol refers to sections to be read carefully.
This symbol refers to sections concerning safety.
This symbol refers to notes to be communicated to users.
Reference to Regulations
The following standards have been complied with for the product:
EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453
Device Description
Wholly designed and built by CAME Cancelli Automatici S.p.A.
Guaranteed 24 months if not tampered with.
Intended for BZ-BX-BK series automation systems.
Infrared protection device composed of:
- Battery-powered transmitter with dip-switches for function
selection.
- 24V AC/DC receivers (DBS01 with interlocked relay contact,
with single outlet), (DBS02, with double outlet), with connections
available for testing operations. 2 active channel LED indicators, 2
dead battery LED indicators.
-Maximum distance transmitter/receiver: 10 m
COMMUNICATION SYSTEM
FOR SAFETY SENSITIVE
EDGES
INSTALLATION MANUAL

Technical Characteristics

Transmitter
Power: 6 V (four 1.5V AAA batteries)
Absorption: 70 µA
Degree of protection: IP54
Material: PC-ABS UL94V0 / Polycarbonate / TPA1 65 NT Marpram mar
Working temperature
Receiver
Power: 24 V a.c. - d.c.
Absorption: 48 mA
Degree of protection: IP54
Material: PC-ABS UL94V0 / Polycarbonate / TPA1 65 NT Marpram mar
Working temperature:
Dimensions and Hole Measurements
Transmitter
Receiver

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dbs02

Tabla de contenido