Best K8087 Manual Del Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
Controls
Your hood is operated using the (5) push buttons located at eye-level, on the front
edge of the hood. It includes an on-off light switch, a filter cleaning alarm, ten-minute
run delay and blower speed settings.
Light switch /
Filter Alarm &
Reset
Light Button, Filter Alarm, Alarm Reset:
Turns halogen lights on and off. Press once to turn the lights ON to low level.
Press a second time to turn the lights on to a brighter level. Press a third time
to turn the light off.
Hoods with grease filter only - when blower is off, this switch remains lit after 30
hours of operation, indicating a need to replace the charcoal filter.
Hood with non-ducted charcoal filter - when blower is off, flashes after 120 hours
of operation, indicating a need to replace the charcoal filter.
After filters are cleaned or replaced, press this button for one-second to reset
the filter alarm.
Blower On-Off, Speed 1
Press once to turn the blower ON to its lowest running speed.
Quickly pressing the switch once delays blower shut off by ten-minutes.
Depress and hold switch down to turn blower off without delay.
Blower Speed 2
With blower running, press switch 2 to change blower speed to medium-low.
Quickly pressing the switch once delays blower shut off by ten-minutes.
To turn off without delay, depress and hold down the 0-1 switch.
Blower Speed 3
With blower running, press switch 3 to change blower speed to medium-high.
Quickly pressing the switch once delays blower shut off by ten-minutes.
To turn off without delay, depress and hold down the 0-1 switch.
Blower Speed 4
With blower running, press switch 4 to change blower speed to high.
Quickly pressing the switch once delays blower shut off by ten-minutes.
To turn off without delay, depress and hold down the 0-1 switch.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF, it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting, it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.
0 - 1
Blower On-
Blower
Off / Speed
Speed 2
1
2
3
Blower
Speed 3
- 4 -
4
Blower
Speed 4

Publicidad

Tabla de contenido
loading

Tabla de contenido