Press the SEL button repeatedly until the corresponding LED comes on.
In this mode only one time is managed (T-On adjustable by potentiometer).
The pump is activated for the set time T-On upon the arrival of a remote activation signal (REM).
When the pump is active it carries out the strikes with the set frequency.
NOTE: If the jumper is not present on the impulse inlet or there is no activation impulse the pump does not start.
Whereas, if there is a jumper at the inlet the pump will see the remote signal (REM) always present and will work
as though it were in constant mode.
REM
Activation
T-On
Using the dip switch 4 an activation delay can be set on the pump compared to the arrival of the remote control.
The delay is programmed using the T-off potentiometer. After the arrival of the remote control, the pump waits for
the amount of time of the set delay before being activated.
REM
Activation
(dip-switch 4 On)
Ritardo (T-Off)
NOTE: With a jumper on the remote signal (REM) inlet and dip-switch 4 ON, the pump will behave in the same way
as the Time On - Time Off mode
Press the SEL button repeatedly until the corresponding LED comes on.
In this mode two timers T-On and T-Off, which can be set by the respective potentiometers, are managed. The
operating mode is cyclical – whilst the power supply remains the pump is active for an amount of time equal to T-on
and stops for an amount of time equal to T-off.
In this mode the remote signal (REM) is disabled, so it has no role.
When the pump is powered it carries out the strikes with the set frequency.
Power Supply
Activation
T-On
Hayward Flow Control
Time On Mode
T-On
Time On-Time Off Mode
T-Off
www.haywardflowcontrol.com
1-888-INDL (1-888-429-4635)
ZTAIOM
Pg. 2 of 3