INSTALL THE ROUGH-IN PLATE
. Run 0" round steel ductwork, from exterior ven-
tilator to the installation location. For best perfor-
mance, use the straightest possible duct run and
the fewest number of elbows. Tape all joints.
2. Run 20 VAC electrical power cable from service
panel and from remote ventilator to installation
location.
3. Remove wiring box cover. Remove knockouts from
the wiring box. Feed 6" of power cable through
openings and attach cables to wiring box with ap-
propriate connectors.
GREEN
EXTERIoR
EXTERIOR
WHITE
VENTILAToR
BLOWER
BLACK
BLACK
WHITE
ROUGH-IN PLATE LEAD
4. Wire black to black, white to white, and green or
bare wire beneath green ground screw. Replace
wiring box cover.
5. Connect ductwork to transition and tape joint.
6. Turn on power and check ventilator operation.
VIKING RANGE
gREENWooD, mISSISSIPPI 38930 USA
WIRING BOX
GREEN
LINE IN
WHITE
120 VAC
BLACK
60 HZ
10 A MAX.
BLACK
WHITE
GREEN
ROUGH-IN PLATE LEAD
USE AND CARE
Disconnect electrical power supply and lock out service
panel before cleaning or servicing this unit.
CLEANING
Remove cover and carefully vacuum ventilator and
inside of housing. Be careful not to bend or otherwise
damage ventilator wheel.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or
disassemble motor.