Troubleshooting - Elvox EI30 Manuales Instrucciones

Actuador enterrado para reja con puertas batientes (alcance: puerta max 2,5m 250 kg.)
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
MECHANICAL END STOP (OPTIONAL)
It is possible to install the mechanical end stop either in opening or in closing setting the two bolts.
EMERGENCY RELEASE PROCEDURE
In order to release the swing of the gate you may insert and turn the key which is on the pivot of the anchoring lever motor reducer/gate.

TROUBLESHOOTING

PROBLEM
On giving a command with the remote control or
with the key-switch, the gate doesn't open or the
motor doesn't start
On giving a command with the remote control, the
gate doesn't open but works with the key com-
mand
The gate starts, but stops immediately
One wing opens and the other closes
N.B. - If the problem persists, contact your Retailer or the nearest Service Centre
EI30
Bolts
PROBABLE CAUSE
230 volt mains voltage absent
Emergency STOP present
Fuse blown
Power cable of motor or motors not connected or
faulty.
The photocell is not functioning or the beam is in-
terrupted
The remote control has not been memorised or the
battery is flat
The force of the motor or motors is insufficient
The connection is not correct
10/28
SOLUTION
Check master switch
Check for any STOP selectors or commands.
If not used, check jumper on STOP contact input
on the control board
Replace with one of same value.
Connect the cable to appropriate terminal or re-
place.
Check the connection, remove any obstacle across
the beam
Carry out the remote control learning procedure on
the radio receiver or replace the battery with a new
one.
Modify the value with the FORCE trimmer on the
control unit
Invert the connection of the cable of the motor
which rotates in the wrong sense.

Publicidad

Tabla de contenido
loading

Tabla de contenido