General; General Terms Of Delivery; Voltage; Water Treatment - PSA ZODIAC Heat line+ 20 Manual De Instalación Y De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37

1. GENERAL

1.1 General terms of delivery

Any equipment, even CARRIAGE and PACKING FREE, travels at the consignee's risk. The consignee
shall make reserves in writing on the carrier's delivery bill if he notes damage caused during the
transport (confirmation to be sent to the carrier within 48 hours by registered mail and Acknowledgement
of Receipt).

1.2 Voltage

Prior to any operation, check that the voltage on the identification plate of the appliance corresponds to
the mains voltage provided on site.

1.3 Water treatment

In order to use our appliances in the best conditions, swimming pool water shall comply with the
following values: free chlorine: max. 2.5 mg/L, total bromine: max. 5.5 mg/L, pH between 6.9 and 8.0.
For any other treatment, the fitter and the user shall apply to the supplier of the planned disinfection's
process (chemical, electrochemical or electro-physical) for the compatibility with the materials of our
appliances. In any case, treatment shall be installed downstream the heating equipment.

2. DESCRIPTION

2.1 Presentation

4
7
2
1- multitubular titanium heat exchanger
2- fittings ½ union PVC Ø63 + reduction Ø50
3- "Bazic" control thermostat
4- circulating pump for primary circuit (female connection Ø26/34)
5- check valve (female connection Ø26/34)
6- flow switch (female connection Ø20/27)
7- pocket for control sensor
8- drain plug for primary circuit (male Ø15/21)
9- adapter for flow switch (Ø15/21 to Ø20/27)
10- orifice blocked (with threading Ø 26/34 female) on exchanger
body 70 kW: never use a primary circuit connection!
3
8
1
2
5
6
9
10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zodiac heat line+ 40Zodiac heat line+ 70

Tabla de contenido