CAT3 PRO CR/TR spring changing device
I
NOTICE
• Ensure that the release flange does not cant when inserted.
BEI.0308.0 • 2021-02-23
G
K
A
L
M
5 Turn the clamp lever (I) counterclockwise
to release the release flange (G).
6 Remove the locating flange (K) and
release flange (G) from the spring
changing device (A).
7 Remove the pressure spring inserts (L) with
pressure springs (M).
The pressure spring inserts (L) are firmly
attached to the pressure springs (M).
The pressure spring inserts (L) can be
removed from the pressure springs (M)
only once the pressure springs have been
disassembled.
8 Mount the new pressure springs with
pressure spring inserts.
9 Assembly takes place in reverse order.
EN - 3