Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

740 East 9th Street, Ashland, OH 44805
Phone: 1-888-957-8677
Fax: 1-888-840-7867
Web Site: http://www.hydromatic.com
Basin Boss
INSTALLATION, OPERATION, & PARTS MANUAL
SAFETY INFORMATION
Carefully read and follow all safety instructions in this
manual or on pump.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for
personal injury!
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The word NOTICE indicates special instructions which are
important but not related to hazards.
1. Read these rules and instructions carefully. Failure to
follow them could cause serious bodily injury and/or
property damage.
2. Check your local codes before installing. You must
comply with their rules.
Hazardous voltage. Can shock, burn, or
kill. During operation the pump is in water.To avoid fatal
shocks, proceed as follows if pump needs servicing:
3A. Disconnect power to outlet box before unplugging pump.
3B. Take extreme care when changing fuses. Do not stand
in water or put your finger in the fuse socket.
3C. Do not modify the cord and plug. When using the cord
and plug, plug into a grounded outlet only. When wiring
to a system control, connect the pump ground lead to
the system ground.
4. Do not run the pump dry. Dry running can overheat the
pump, (causing burns to anyone handling it) and will
void the warranty.
5. The pump normally runs hot. To avoid burns when
servicing pump, allow it to cool for 20 minutes after shut-
down before handling it.
PUMP, MOTOR, SWITCH, & CORD SPECIFICATIONS
Model
Motor
Number
HP
HBB-SKV40
4/10
HBB-SKV50
1/2
© 2008
Individual
Motor Full
Branch Circuit
Load Amps
Required (Amps)
12.6
20
12.0
15
Models HBB-SKV40
6. The pump is permanently lubricated. No oiling or
greasing is required in normal operation. for overhaul,
see instructions under "Service".
7. Vent sewage or septic tank according to local codes.
8. Do not install the basin or pump in any location
classified as hazardous by the United States National
Electrical Code (NEC), or by the Canadian Electrical
Code (CEC), where applicable.
PUMP SPECIFICATIONS
Power Supply Required .................................................115V
Individual Branch Circuit Required:
HBB-SKV40 ........................................................20 Amps
HBB-SKV50 ........................................................15 Amps
Maximum Liquid Temperature:
HBB-SKV40 ..................................................120°F(49°C)
HBB-SKV50 ..................................................140°F(60°C)
Discharge Adapter..................................................... 2" NPT
DESCRIPTION
The Hydromatic Basin Boss™ with Easy Out is ideal for
basement installations, pumping below-grade toilets, and
laundry facilities. It includes a submersible sewage pump
and a premium heavy duty structural foam, corrosion
resistant sump/sewage basin and lid for easy installation.
This submersible pump is designed for effluent and
wastewater removal, sump drainage, dewatering and flood
control. The pump has built in thermal overload protection
and an automatic reset. The mechanical seal and bearings
on the motor shaft are permanently lubricated. Stainless
steel hardware and a heavy duty lift out handle allow for
easy disassembly after extended use.
The basin is used for residential, commercial, and industrial
collection of sewage, effluent drainage and seepage water.
The basin cover kit includes an inlet hub, a gas tight cover,
cord seals, gaskets, and hardware. No special tools or
sealants are required.
NOTICE: This unit is not designed for applications involving salt
water or brine! Use with salt water or brine will void warranty.
Switch Setting in inches (mm)
Cord Length
in ft. (m)
On
10 (3.0)
11-3/4" (298)
10 (3.0)
11-3/4" (298)
HBB-SKV50
Discharge
Adapter
Off
Size
5-3/4" (145)
2"
5-3/4" (145)
2"
W-03-497 (Rev. 11/3/09)
056254971

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Hydromatic Basin Boss HBB-SKV40

  • Página 1 DESCRIPTION property damage. The Hydromatic Basin Boss™ with Easy Out is ideal for 2. Check your local codes before installing. You must basement installations, pumping below-grade toilets, and comply with their rules.
  • Página 2 PERFORMANCE Connect or wire pump to its own individual branch circuit with no other outlets or equipment in the circuit. Size fuses or circuit breakers according to the “Motor, Switch and Cord GPM AT TOTAL FEET Specifications” chart. Model No flow at height CAPACITY GALLONS/MINUTE shown below...
  • Página 3 8. Install the 2" check valve in the horizontal portion of the 12. Check the operation by filling the basin with water and discharge pipe. See Figure 1. Make certain the flow observing pump operation through one complete cycle. indicating arrow points away from the pump. This check Make sure that no parts of the assembly interfere with the valve will keep the water from running back into the basin float.
  • Página 4 3 3A Drowning risk to small children. Do not leave small children unattended near basin if lid is off of basin. 5747 1207 REPAIR PARTS – PRE-PLUMBED SYSTEMS Part Description Qty. Part No. Float Tree 27627B040 Cord Clamp 27627B041 Hatch Cord Grommet Hatch Gasket Vent Grommet...
  • Página 5 TROUBLES-REMEDIES Sudden Starts. If the power is on to the pump when thermal overload resets, the pump may start without warning. If you are working on the pump, you may get an electrical shock or the impeller may catch fingers or tools. Disconnect the power before servicing the pump.
  • Página 6 Your only remedy, and HYDROMATIC’s only duty, is that HYDROMATIC repair or replace defective products (at HYDROMATIC’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired.
  • Página 7: Système De Bassin

    DESCRIPTION Lire attentivement et suivre exactement toutes les instructions et toutes Le système de bassin Hydromatic avec Easy Out est idéal pour les les consignes de sécurité figurant dans cette notice. Si on ne respecte installations, les toilettes et les salles de lavage en sous-sol. Il est livré...
  • Página 8 RENDEMENTS Pour le fonctionnement en automatique de la pompe, la brancher dans un interrupteur à flotteur à fonctionnement automatique ou bien la câbler sur un tel interrupteur; on peut aussi la brancher sur un contrôleur duplex. La pompe L/min (Gal/min) à la hauteur totale de refoulement metres (pi) fonctionnera en permanence si elle est directement branchée dans une prise Aucun débit à...
  • Página 9 Poser un clapet antiretour de 2 pouces sur la partie horizontale du tuyau 12. Vérifier le fonctionnement du système en remplissant le bassin d’eau de refoulement. Se reporter à la Figure 1. S’assurer que la flèche et observer le fonctionnement de la pompe sur un cycle complet. indiquant le sens du débit est orientée à...
  • Página 10 3 3A AVERTISSEMENT Les enfants risquent de se noyer. Ne pas laisser de jeunes enfants sans surveillance près du bassin si son couvercle n’est pas en place. LISTE DES PIÈCES DE RECHANGE DES SYSTÈMES À TUYAUTERIE DÉJÀ INSTALLÉE Désignation Réf. des pièces Qté...
  • Página 11: Pannes Et Remèdes

    PANNES ET REMÈDES Démarrages soudains. Si la pompe est alimentée en courant électrique lorsque le dispositif de protection contre les surcharges se réenclenche, elle risque de démarrer sans qu’on s’y attende. Si, à ce moment-là, on intervient sur la pompe, on risque de subir une secousse électrique, de se coincer les doigts dans l’impulseur ou bien les outils risquent de se coincer dans l’impulseur.
  • Página 12: Garantie Limitée

    Le seul recours de l’Acheteur et la seule responsabilité de HYDROMATIC consistent à réparer ou à remplacer (au choix de HYDROMATIC) les produits qui se révéleraient défectueux. L’Acheteur s’engage à...
  • Página 13 El sistema para lavabo Hydromatic con Salida Fácil es ideal para Consulte sus códigos locales antes de la instalación. Usted instalaciones en sótanos, para bombear inodoros debajo del nivel deberá...
  • Página 14: Instalación

    DESEMPEÑO Es importante conectar o cablear la bomba a su propio ramal individual sin otro tomacorriente ni aparato conectado al circuito. Determine el tamaño de los fusibles o disyuntores según la tabla de GPM A ALTURA TOTAL EN PIES "Especificaciones para el Motor, el Interruptor y el Cordón Eléctrico". Modelo No hay flujo a la altura...
  • Página 15: Operación

    Instale la válvula de retención de 2" en la porción horizontal de la 12. Verifique el funcionamiento llenando el depósito con agua y tubería de descarga. Consulte la Figura 1. Asegúrese de que la observando el funcionamiento de la bomba por un ciclo completo. flecha que indica el flujo señale en dirección opuesta a la bomba.
  • Página 16 3 3A ADVERTENCIA Peligro de ahogo para niños pequeños. No deje niños pequeños sin supervisión cerca del depósito si se ha retirado la tapa. 5747 1207 PIEZAS DE REPARACIÓN – SISTEMAS CON INSTALACIÓN SANITARIA Clave Descripción de la pieza Cant. Pieza No.
  • Página 17: Problemas - Soluciones

    PROBLEMAS – SOLUCIONES Arranques repentinos – Si la corriente a la bomba está activada cuando se reposiciona el protector de sobrecarga térmica, la bomba puede comenzar a funcionar sin previo aviso. Si usted está trabajando en la bomba, puede recibir un choque eléctrico o el impulsor puede atrapar los dedos o las herramientas. Desconecte la corriente antes de realizar servicios de reparación o mantenimiento en la bomba.
  • Página 18: Garantía Limitada

    2-1/2" de marca Hydromatic están garantizadas por un período de 12 meses a partir de la fecha de compra, o durante 18 meses a partir de la fecha de su fabricación, según lo que ocurra primero.