Descargar Imprimir esta página

Vimar BY-ME Eikon Serie Guia De Inicio Rapido página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Eikon
Arké
Idea
20516
19516
16956
Infrared remote control receiver - 2 modules.
This device receives commands from the remote control 01849 and has 4 chan-
nels in reception. It can be used for the functions of an On/Off switch, roll-up blind
control, dimmer control, state reversal control (step-by-step), scenario activation.
CHARACTERISTICS.
• Rated supply voltage: BUS 29 V
• Input: 10 mA
• Input: remote control 01849 (IR protocol RC5)
• Reception channels: 4
• Terminals: TP BUS
• Possible functions:
- ON/OFF switch
- roller shutter control
- dimmer control
- state reversal (step-by-step)
- button
- scenario activation.
CONFIGURATION.
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE
THE By-me SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE
CONTROL UNIT.
• Functional blocks: 4, each functional block can belong to at most 4 groups.
• Selecting the functional block (configuration): during group creation, when the
control unit requires pressing the device button:
• Operation type 1: step-by-step or simple button (pressed ON, released OFF):
- press the configuration button;
- the LED light illuminates and blinks;
- select the functional block to configure with a button from 1 to 4 on the remote
control (right or left-hand buttons of the remote control indistinctly);
- the LED blinks;
- press the button of the remote control you want to associate with the functional
block;
- the LED blinks slowly; at the end of the operation the LED will go out.
• Operation type 2: ON/OFF button, dimmer control or roller shutter control
- press the configuration button;
- the LED light illuminates and blinks;
- select the functional block to configure with a button from 1 to 4 on the remote
control (right or left-hand buttons of the remote control indistinctly);
- the LED blinks;
- press the button of the remote control you want to associate with the functional
block;
- the LED blinks slowly;
- within 3 s press the button next to the one pressed before (which is the button
next to the one associated with the functional block);
- the LED comes on; at the end of the operation the LED will go out.
Notes.
• In "step-by-step or simple button operation" configuration it is possible to
pass from "step-by-step button" to "simple button" operation by changing the
parameters.
• In "ON/OFF button, dimmer control or roller shutter operation" configuration it is
possible to pass from "ON/OFF button" to "dimmer control button" and "roller
shutter control button" by changing the parameters.
PARAMETERS.
• For each functional block it is possible to set the operating mode:
- Operation type 1:
- ON/OFF button (step-by-step);
- Operation type 2:
- simple button (ON when pressed, OFF when released);
- ON/OFF button;
- dimmer control button;
- roller shutter button;
- scenario control;
Viale Vicenza, 14 - 36063 Marostica VI - Italy
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188
Fax (Export) +39 0424 488 709
www.vimar.com
Plana
14516
FRONT VIEW.
Arké
Eikon
A B C
A B C
Idea
Plana
A B C
A B C
Caption:
A: IR receiver
B: led
C: configuration button.
• LED parameters:
- LED always off;
- LED normally off (except when on IR reception);
- LED normally on for location in the dark (except when on IR reception).
• Default parameters: ON/OFF button with LED always on.
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for electri-
cal systems in the country where the products are installed. For further instructions,
please see the manual attached to the control panel.
CONFORMITY.
EMC directive
Standard EN 50428.
BACK VIEW.
terminals
TP bus

Publicidad

loading

Este manual también es adecuado para:

By-me arke serieBy-me idea serieBy-me plana serie205161951616956 ... Mostrar todo