Ocultar thumbs Ver también para ILB9:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

IN-LINE BLOWERS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electri-
cal wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when flambe-
ing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef
Flambe').
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
!
FOR DOMESTIC COOKING ONLY
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such
as an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further information
and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
"TYPICAL INSTALLATION"
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring
"MOUNTING OPTIONS"
"WIRING PLATE POSITION"
"DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (Vertical blower discharge)
"USE AND CARE"
"SERVICE PARTS"
"WARRANTY"
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
ILB9  ILB11
MODELS
Page 1
!

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Best ILB9

  • Página 1 ILB9  ILB11 MODELS Page 1 IN-LINE BLOWERS READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 4. Use an extinguisher ONLY if: TO PERSONS, OBSERVE THE FOLLOWING: A. You know you have a Class ABC extinguisher and you already know how to operate it. 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or B. The fire is small and contained in the area where it started.
  • Página 2: Typical Installation

    ILB9  ILB11 MODELS Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) MOUNTING USING HANGER KIT (included) 10” ROUND DUCT 8” X 12” TO 8” X 12” TO 8” X 12” TO (OUTLET) 10” ROUND HANGER 10” ROUND 10” ROUND TRANSITION KIT BOLT TRANSITION TRANSITION (FEMALE) (FEMALE) & WASHER (MALE) EXTENSION SPRING 10” ROUND DUCT HANGER 10” ROUND...
  • Página 3: Mounting Options

    ILB9  ILB11 MODELS Page 3 WIRING WIRING PLATE POSITION BLACK BLACK EDGE OF HOUSING GROUND TO VERTICAL WIRING PLATE POWER CABLE CONNECTION WIRING PLATE HORIZONTAL POWER CABLE CONNECTION WHITE Wiring plate mounts to side or top of housing. WHITE 120 VAC LINE IN DUCTING OPTIONS (from range hood) Ventilator can be wired from outside of housing.
  • Página 4: Service Parts

    ONE YEAR LIMITED WARRANTY FOR BEST PRODUCTS Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Best products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase.
  • Página 5: Ventiladores Para Montaje En Línea

    MODELOS ILB9  ILB11 Página 5 VENTILADORES PARA MONTAJE EN LÍNEA LEA Y CONSERVE ESTAS INSTRUCCIONES PARA COCINAR EN CASA SOLAMENTE ADVERTENCIA ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO, GOLPE ELÉCTRICO, O LESIÓN 4. Utilice un extinguidor SOLAMENTE si: A PERSONAS, OBSERVE LO SIGUIENTE: A.
  • Página 6: Instalación Típica

    MODELOS ILB9  ILB11 Página 6 INSTALACIÓN TÍPICA INSTALACIÓN TÍPICA MONTAJE (Estructura nueva) MONTAJE EL USAR KIT DE SUSPENDER (incluido) TRANSICIÓN 8” X 12” TRANSICIÓN (20,3 X 30,5 cm) A 8” X 12” TRANSICIÓN REDONDO DE 10” (20,3 X 30,5 cm) A TORNILLO Y DE 8” X 12” A (25,4) (MACHO) REDONDO DE 10” ARANDELA 10” REDONDA (25,4) (HEMBRA)
  • Página 7: Colocación De La Placa De Conexiones

    MODELOS ILB9  ILB11 Página 7 CONEXIONES ELECTRICAS COLOCACIÓN DE LA PLACA PARTE SUPERIOR/POS- NEGRO A DE CONEXIONES NEGRO TERIOR DEL ALOJA- ENTO TIERRA A LA PLACA DE CONEXIO- PLACA DE CONEXIÓN CONEXIONES VERTICAL DEL CABLE DE ALI- MENTACIÓN LÍNEA DE BLANCO CONEXIÓN ENTRADA DE...
  • Página 8: Uso Y Cuidado

    En el momento de solicitar servicio cubierto por la garantía, usted debe de presentar evidencia de la fecha original de compra. En los Estados Unidos: BEST , 926 W. State Street, Hartford, Wisconsin 53027 800-558-1711 En Canada: BEST , 550 Lemire Blvd., Drummondville (Quebec) Canada J2C 7W9 866-737-7770 www.BestRangeHoods.com ®...
  • Página 9 MODÈLES ILB9  ILB11 Page 9 VENTILATEURS MONTAGE DANS LIGNE LIRE ET CONSERVER CES INSTRUCTIONS POUR USAGE DOMESTIQUE SEULEMENT AVERTISSEMENT AVERTISSEMENT 3. N’UTILISEZ JAMAIS D’EAU, incluant les linges à vaisselles ou serviettes POUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC ÉLECTRIQUE OU DE mouillés car cela peut provoquer une violente explosion de vapeur.
  • Página 10: Installation Typique

    MODÈLES ILB9  ILB11 Page 10 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) MONTAGE EN UTILISANT LE KIT DE CINTRE (inclus) CONDUIT CIRCULAIRE DE 10 po (25,4 cm) (sortie) TRANSITION DE VIS ET TRANSITION DE TRANSITION DE 8 x 12 po au 8 x 12 po au RONDELLE DE 8 x 12 po au 10 po circulaire...
  • Página 11: Options De Montage

    MODÈLES ILB9  ILB11 Page 11 POSITION DE LA CÂBLAGE PLAQUE DE CÂBLAGE NOIR AU DESSUS / NOIR ARRIÈRE DU BOÎTIER FIL DE TERRE À PLAQUE DE CÂBLAGE BRANCHEMENT PLAQUE DU CÂBLE D’ A LIMENTATION CÂBLAGE À LA VERTICALE ENTRÉE BRANCHEMENT DU 120 VCA CÂBLE D’ A LIMENTATION BLANC (du le hotte) À L’HORIZONTALE BLANC La plaque de câblage se fixe sur le côté ou sur le dessus du Le ventilateur peut être branché...
  • Página 12: Utilisation Et Entretien

    Au moment de la demande de service sous garantie, vous devez présenter une preuve de la date d’achat original du produit en question. Aux E.U. : BEST , 926 W. State Street, Hartford, Wisconsin 53027 800-558-1711 Au Canada : BEST , 550 Lemire Blvd., Drummondville (Quebec) Canada J2C 7W9 866-737-7770 www.BestRangeHoods.com ®...

Este manual también es adecuado para:

Ilb11

Tabla de contenido