CLEANING SEDIMENT CUP
CAUTION:
VENTILATED AREA, AWAY FROM SPARKS OR
FLAME, INCLUDING ANY APPLIANCE WITH A
PILOT LIGHT.
LOW FLASH-POINT SOLVENT TO CLEAN THE
FUEL VALVE.
RESULT.
NOTE:Clean sediment cup after every 100 hours of use.
1.
Turn fuel valve (A) to left as illustrated to shut off the fuel flow.
2.
Remove cap screw (B) with a 10mm wrench. Remove sediment cup (C) and o-ring.
3.
Remove any sediment or other foreign matter and wash in nonflammable or high
flash point solvent. Dry thoroughly.
4.
Install o-ring and sediment cup with cap screw.
5.
Turn fuel valve right to "ON" position and check for fuel leaks.
HONDA
16
SERVICE
CLEAN SEDIMENT CUP IN A WELL
DO NOT USE GASOLINE OR A
A FIRE OR EXPLOSION COULD
A
C
B
Trash Pump Operator's Manual