Tubing Connections - LMI Excel XR Serie Guia De Inicio Rapido

Ocultar thumbs Ver también para Excel XR Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
The injection check valve prevents backflow from a treated line.
Install the injection check valve at the location where chemical is
1.
being injected into the system. Any size ½ inch female NPT fitting
will accept the injection check valve.
Position the valve so that it enters the bottom of your pipe in a
2.
vertical position.
Connect tubing to the injection check valve then back to the
3.
discharge side of the pump head.

5.0 Tubing Connections

Use only LMI supplied tubing with your pump, as the tubing is
specifically designed for use with the pump fittings. Before
installation, all tubing must be cut with a clean square end.
DO NOT USE PLIERS OR PIPE WRENCH ON COUPLING NUTS
OR FITTINGS.
DO NOT REUSE FERRULES — USE ONLY NEW FERRULES.
Insert tubing through coupling nut. The tubing should enter the smaller
1.
end of the coupling nut first, orienting the larger opening of the coupling
nut toward the tubing end.
Position a female ferrule about 1 in (25 mm) from end of tubing. For 3/8
2.
in and 8 mm tubing, orient the raised collar of the female ferrule toward
the coupling nut.
Insert the male ferrule onto the end of the tube, pushing the tube
3.
into the bottom of the groove or base.
Slide the female ferrule down the tubing and with your fingers,
4.
press tightly into the male ferrule.
Firmly hand tighten the coupling nut onto the fitting.
5.
4
INSTALLATION
PTFE Tape
on Pipe
Attachment
Only
Coupling Nut
Ferrule (Female)
Tube
3/8" or 8mm
Hose
1/4"x1/2" or 6x12mm
Ferrule (Male)
O-Ring
Fitting
Pipe
Cross-Section
Injection
Check-Valve
Coupling Nut
Tube 1/2"
Ferrule (Female)
Ferrule (Male) / Fitting