150TL-PTA (REV. B)
ENGLISH
IN U.S.A.: Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293
SDC15
1.5A DUAL FAN CONTROL/300W DIMMER, 120V - 60 Hz
Warning: Turn circuit breaker to OFF position or remove fuse(s) and test that power is off before wiring. Never wire any electrical device with power
turned on. Wiring fan control hot may cause permanent damage to this device and other equipment and void warranty.
Warnings and Cautions:
• Must be installed and used in accordance with all national and local electrical codes.
• For use with permanently installed split capacitor or shaded pole motors used in ceiling fans. To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lights, transformer-supplied appliances, etc.
• Use only with permanently installed 120V AC 60 Hz fixtures.
• Do not exceed 300W max. rating of the dimmer or 1.5 Amp max. current rating of the fan control.
• If a bare copper or green ground connection is not available in the wallbox, contact a licensed electrician for installation.
• Use only #14 or #12 copper wire with this device. DO NOT USE WITH ALUMINUM WIRE.
Ganging/Multi-Device Application:
No derating is required when ganging multiple fan controls in one wall box.
Operation
Dimming Control: Raise slide to increase light level, lower slide to decrease light level. Move slide to minimum position to turn lights off.
Fan Control: Raise slide to increase fan speed, lower slide to decrease fan speed. Move slide to minimum poistion to turn fan off.
General wiring instructions:
Strip wires in wall box to expose 3/4" of copper on the end of each wire.
If using the terminal screws, wrap stripped wires 3/4 turn clockwise under heads of screws without overlapping and tighten securely.
If using backwire connection, (use back wire strip length gage on back cover) insert and hold stripped wires in backwire opening while tightening the terminal screw securely. Tighten
terminal screws securely.
Installation instructions:
Step 1:
Remove existing switch wallplate and device mounting screws. Pull out switch (DO NOT remove wires)
1
Remove wallplate and pull out switch
Turn off power
Step 2:
Identify existing wiring. Note: If the wiring in the wallbox does not resemble any of these configurations, contact an electrician.
1.
2.
3.
4.
See Figure 4 wiring diagram
Step 3:
Disconnect switch wiring
Step 4:
Refer to Figure 4 Single Pole wiring diagram
FIGURE 4: SINGLE POLE WIRING
1.
Green or bare copper wire in wallbox to green screw terminal
2.
Line Hot wallbox wire to screw terminal marked BK
3.
Fan: Hot wallbox wire to screw terminal Fan on back
4.
Light: Hot wallbox wire to screw terminal marked light on back
5.
Go to Step 5
Black
Noir
Negro
Bare
Nu
Desnudo
Black
Noir
Negro
Identify existing wiring (This switch will be a single-pole)
Single Pole
Line (Hot)
1
Neutral
2
Ground
Load
3
4
BK
YL
YL
Black
{
Load
Load
Green
Ground
White
Step 5:
Testing the fan control:
1. Ensure the word "TOP" is facing up on the device.
2. Partially screw in mounting screws in wallbox mounting holes.
3. Restore power at circuit breaker or fuse.
4. If the fan does not turn on, press the switch on the fan control.
Step 6.
Completing Installation
WIRE COLOR CHART
1. Turn off the power at the circuit breaker or fuse(s)
2. Gently push wires and fan control into wall box and secure, using
White–Neutral Wire
Zero Voltage
mounting screws. Ensure that fan control is positioned so that symbol
Black–Hot Wire
"TOP" stamped into metal strap appears at top.
Full Voltage
3. Secure the wallplate to the device.
Red–Hot Wire
4. Restore power at the circuit breaker or fuse(s).
Full Voltage
5. Test fan control again. Installation is complete.
White, Black Markings–Hot Wire
Full Voltage
Product Information
Green–Ground
Serves as grounding pathway
For technical assistance, contact Cooper Wiring Devices at 866-853-4293 or fax to 800-329-3055 or visit our website at www.cooperwiringdevices.com
Bare Copper–Ground
Serves as grounding pathway
For a period of 2 years from the date of purchase, Cooper Wiring Devices will replace or repair the fan control provided that it has not been subject to abuse, improper installation or improper use, and is returned
prepaid to Cooper Wiring Devices Quality Control Department at 203 Cooper Circle, Peachtree City, GA 30269. If the product has been discontinued, replacement will be made with the nearest available equivalent
model. This warranty does not cover consumables (such as fuses). Proof of purchase in the form of a bill of sale or receipted invoice that shows that the item is within the applicable warranty period must be pre-
sented to obtain the repair or replacement provided by the warranty. Repair or replacement as provided under this warranty is the exclusive remedy of the customer. Cooper Wiring Devices shall not be liable for
any incidental or consequential damages for breach of any express or implied warranty on any of its products. Except to the extent limited or prohibited by applicable law, any implied warranty of merchantability or
fitness for a particular purpose on this product is limited in duration to the duration of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations
on how long an implied warranty lasts, so the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
FRANÇAIS
IN CANADA: Cooper Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8 • 800-267-1042
SDC15
White
Blanc
1.5 A COMMANDE DOUBLE : VENTILATEUR/300 W GRADATEUR, 120 V - 60 HZ
Blanco
Avertissement : Ouvrir le disjoncteur ou retirer le ou les fusibles et contrôler que l'alimentation est coupée avant de procéder au câblage.
Ne jamais câbler un appareil électrique sous tension. Le câblage de la commande du ventilateur sous tension peut provoquer des dégâts
permanents à cet appareil et annuler la garantie.
Messages d'avertissement et de prudence :
• Doit être installée et utilisée conformément à tous les codes électriques nationaux et locaux.
• Pour utilisation avec condensateur auxiliaire ou moteurs à bague de déphasage installés de façon permanente dans les ventilateurs de
plafond. Afin d'éviter une surchauffe et une détérioration possible d'autres équipements, ne pas utiliser pour le contrôle des prises, des
appareils d'éclairage fluorescents, des appareils à alimentation par transformateur, etc.
• N'utiliser qu'avec des appareils 120 V CA 60 Hz installés de façon permanente.
• Ne pas dépasser 300 W max. pour le gradateur et 1,5 Amp max. pour le courant nominal de la commande de ventilateur.
• Si une connexion de terre verte ou en cuivre nu n'est pas disponible dans la prise murale, contacter un électricien agréé pour
l'installation.
• N'utiliser que des fils en cuivre n° 14 ou n° 12 avec cet appareil. NE PAS L'UTILISER AVEC UN FIL EN ALUMINIUM.
Application de regroupement/à plusieurs appareils :
Aucun déclassement n'est requis lors de la juxtaposition de plusieurs commandes de ventilateur dans un seul boîtier mural.
Utilisation
Commande de gradateur : Déplacer la glissière vers le haut pour augmenter la luminosité et vers le bas pour la diminuer. Déplacer la glissière vers le bas pour éteindre la lumière.
Commande de ventilateur : Déplacer la glissière vers le haut pour accélérer le ventilateur et vers le bas pour le faire ralentir. Utiliser l'interrupteur pour démarrer ou arrêter le ventilateur.
Instructions générales de câblage :
Hot (Black)
Dénudez les fils dans la prise murale afin d'exposer 20 mm de cuivre à l'extrémité de chaque fil.
En cas d'utilisation de vis de bornes, enroulez chaque fil dénudé de 0,75 tour dans le sens horaire sous la tête des vis, sans chevauchement, et serrez bien.
En cas de connexion arrière (utilisez le gabarit de longueur de dénuement du fil arrière sur le couvercle arrière), insérez et maintenez les fils dénudés dans l'ouverture arrière tout
en serrant bien la vis de borne. Serrez les vis de bornes.
Notice de montage :
Étape 1 :
Enlevez la plaque murale de l'interrupteur et les vis de montage de l'appareil. Extrayez l'interrupteur (N'enlevez PAS les fils).
Line
1
120V AC - 60 Hz
Couper l'alimentation
Neutral (White)
YOUR COOPER WIRING DEVICES ASSEMBLED PRODUCT TWO YEAR LIMITED WARRANTY
Retierer la plaque murale et extraire la commutateur
TABLEAU DES COULEURS DES FILS
Blanc-Fil Neutre
Tension Zéro
Noir-Fil Sous Tension
Pleine Tension
Rouge-Fil Sous Tension
Pleine Tension
Blanc, Marquage Noir-Fils Sous Tension
Pleine Tension
Vert-Terre
Sert de mise à la terre
Cuivre nu-Terre
Sert de mise à la terre
Black
Noir
Negro
Bare
Nu
White
Desnudo
Blanc
Blanco
Black
Noir
Negro
Identifier le câblage existant
(ce commutateur sera unipolaire)

Publicidad

loading

Resumen de contenidos para Cooper SDC15

  • Página 1 Fan Control: Raise slide to increase fan speed, lower slide to decrease fan speed. Move slide to minimum poistion to turn fan off. For a period of 2 years from the date of purchase, Cooper Wiring Devices will replace or repair the fan control provided that it has not been subject to abuse, improper installation or improper use, and is returned prepaid to Cooper Wiring Devices Quality Control Department at 203 Cooper Circle, Peachtree City, GA 30269.
  • Página 2 Blanco Pendant une période de deux ans à partir de la date d’achat, Cooper remplacera ou réparera commande de ventilateur pourvu qu’il n’ait pas été soumis à un usage abusif, qu’il n’ait pas été mal installé et qu’il n’ait pas été mal utilisé, et qu’il soit retourné en port payé au Service du contrôle de la qualité de Cooper Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. Si le produit ne se fait plus, le remplacement par le modèle équivalent le plus récent sera effectué.