4
Information of display values
Switch position: "Voltage"
display
less than 10,5 V
10,5 V to 11,5 V
11,5 V to 12,5 V
12,5 V to 12,8 V
12,8 V to 14,2 V
more than 14,5 V
Switch position: "Current"
display
-0,1
to
0,1 A
0,1
to
1,0 A
1,0
to
20,0 A
-0,1
to
-20,0 A
information
- Battery totally discharged
switch off all consumers!
- Battery discharged to a high
degree, limit consumption!
- Normal operating condition
- Battery totally charged,
no load connected
- Battery is being charged,
no large load connected
-
Warning High voltage, switch off
charge current!
information
- No charge current flowing
cable break, too dark.
- Normal charge current with
cloudy sky or modules partially
shaded.
- Charge current with sunshine,
level directly dependent on solar
module size.
- Discharge current of the
consumers, level directly
dependent on consumers.