fadini Elpro 980 Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Elpro 980
GB
LOW VOLTAGE ELECTRIC CONNECTIONS
Accessory
Radio contact
1
2
4
3
5
7
6
8
A
9
S T
O
P
B
F A
D I
N I
ELECTRICAL POWER CONNECTIONS
Accessory
Motor
Flashing lamp:
l'apr ican
cello
Power supply
6 5
4 5
LT
24 0
VO
230 VOLT
FUNCTIONS
Description
Automatic/semi-automatic:
Automatic cycle: on pulsing to open, the beam rises and stays open (up position) on dwell as
long as the time set on trimmer T2 expires, then it lowers automatically.
Semi-automatic cycle: on pulsing to open, the beam rises. Another pulse is needed for the
beam to lower.
Deadman (hold on switched) control:
Open and close operations are achieved by "holding a switch on"
(no relay self-holding is involved) therefore a physical attendance is
required to keep the barrier opening or closing until either the
button or key is released.
External time clock (optional):
Time clock: Elpro 980 allows a standard time clock to be
connected to it.
Connections: parallel connect the NO contact of the clock to
the terminal n° 4 OPEN and n° 3 COMMON, and set the board
to the automatic mode by Dip-Switch n° 3 = ON.
How it works: set the clock to the required opening time.
At the pre-set time the barrier is automatically opened and
held open (the lamp goes off and the led flashes twice shortly
and a longer pause follows). Any further pulsing (even by
remote control) is not accepted by the system until the time
pre-set by the clock has expired. On expiring, and after the
pre-set dwell time, the barrier is closed automatically.
ELECTRONIC CONTROL BOARD FOR ROAD BARRIERS BAYT 980
Electrical connections
- Open/close (standard)
3
7
- Any new pulse reverses direction
- Step by step
Electrical connections
MOTOR RUN TIME:
no motor run TRIMMER is fitted, run
time is controlled through the limit
switches and is factory preset at
25 s max. (Max. time required is 19 s
Bayt 980 with 8 m beam and skirt)
The board is supplied with power after connecting the cut off
switch to the 230 V - 50 Hz mains
BAYT 980
Oleodinamica
External clock
3 4
NO
10
Dip-Switch setting and LED indication of functions
DIP-SWITCH N° 2:
ON: no reversing on opening
OFF: any pulse reverses travel direction
2
DIP-SWITCH N° 5:
ON: step by step, stop in between
OFF: standard operations
5
Dip-Switch setting and LED indication of functions
DIP-SWITCH N° 4:
ON: pre-flashing
OFF: no pre-flashing
4
DIP-SWITCH N° 8:
ON: lamp out of service on dwell time,
automatic mode
8
OFF: lamp flashes on dwell time automatic mode
Dip-switch setting and LED indication of functions
DIP-SWITCH N° 3:
ON: automatic closing
OFF: no automatic closing; semi-automatic mode
3
DWELL TIME from 0 to 180 s
DIP-SWITCH N° 6:
ON: deadman control
OFF: standard operating mode
6
DIP-SWITCH N° 3:
ON: automatic closing
OFF: no automatic closing; semi-automatic mode
3

Publicidad

Tabla de contenido
loading