Physical specifications

Ambient operating
temperature range
Peso
PROBLEM
No power, no indicator.
The Red LED indicator lights ( B2C)
The Green LED indicator blinks (B3)
Inverter runs small loads but
not large loads
Water entered
Measured inverter output
is too low
Battery run time is less
than expected

SERVICE INFORMATION

BLACK+DECKER offers a full network of company-owned and authorized service locations. All BLACK+DECKER
Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool service.
For more information about our authorized service centers and if you need technical advice, repair, or genuine factory
replacement parts, contact the BLACK+DECKER location nearest you, or visit us at www.BlackandDecker-la.com
All manuals and user guides at all-guides.com
32ºF ~ 104ºF
(0ºC ~ 40ºC)
0,142 kg (0,31 lb)

TROUBLESHOOTING

POSSIBLE CAUSE
Battery is defective
Blown fuse
Lose connections
AC products connected are rated at
more than 100W; overload shutdown
has occurred.
AC products are rated less than
100W, but high starting surge has
caused overload shutdown.
The voltage input is too low. Low
voltage shut off occurs.
Inverter is overheated due to poor
ventilation and has shut down.
Low voltage battery
Water entered the unit
Standard "average-reading" AC
voltmeter used to measure output
voltage, resulting in an apparent
reading 5 to 15V too low.
Battery voltage is too low
AC product power consumption is
higher than rated.
Battery is old or properly defective.
Battery is not being properly charged.
ENGLISH • 19
POSSIBLE SOLUTION
Replace battery
Check and replace fuse
Check connections, be sure the ports
and plugs come into contact with
each other.
Reduce load, use a product with
power rating less than 100W.
Use a product with starting surge
power within the inverter's capability
(≤ 200W).
Charge the battery
Unplug inverter from DC socket and
allow to be cooled for 15 minutes.
Remove objects covering unit. Move
the inverter to a cooler place. Reduce
load if continuous operation is
required. Restart.
Charge the battery
Disconnect the inverter and wipe
immediately with a dry cloth, or
permanent damage can occur with
liquid ingress.
Inverter's "modified sine
wave" output requires "true
RMS" voltmeter for accurate
measurements.
Recharge battery
Use a larger battery to make up for
increased power requirement.
Replace battery
Some chargers are not able to fully
recharge a battery. Make sure you us
e a powerful charger.