Blue Angel BRPP50T Manual De Instrucciones

Bomba de aguas negras de hierro fundido

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Please read and save these instructions. Read carefully before attempting
to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to
comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
Operating Instructions
Description
This sewage pump is suitable for pumping
sewage, effluent, wastewater, and
groundwater with up to two inch solids.
The BRPP50T pump includes a wide angle
float switch that turns the pump on and
off as the fluid level rises and falls. The
BCAPRPP50 is provided with a "Cap
Switch" capacitive water sensor. When
water is detected, the pump will start
automatically. These pumps are intended
for use in domestic sewage lift stations.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Specifications
Power supply requirements
Circuit requirements
Motor duty
Motor
Horsepower
Motor full load
Liquid temperature range
Max. operating position
Dimensions
Intake
Discharge
Cut-in level (factory set)
Cut-out level (factory set)
Differential
Switch
Power cord
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2008 Blue Angel™ Pumps
1/2 HP Cast Iron
Sewage Pump
an imminently hazardous situation
which, if not avoided, will result in
death or serious injury.
a potentially hazardous situation
which, if not avoided, could result in
death or serious injury.
a potentially hazardous situation
which, if not avoided, MAY result in
minor or moderate injury.
important information, that if not
followed, may cause damage to
equipment.
General Safety
Information
CALIFORNIA PROPOSITION 65
or its power cord may contain
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
BRPP50T
120V, 60 hz
15 amps (min)
Intermittent
120V, 1 Phase
1/2
6.3 amps
40°F to 120°F
45
o
from vertical
14" x 12"
2"
2" NPT female
16"
7.5"
8.5"
90
o
wide angle
mechanical tether switch
18 gauge 3 Conductor
with plug
For parts, product & service information
visit www.blueangelpumps.com
Models BRPP50T and BCAPRPP50
Danger
indicates
Warning
indicates
Caution
indicates
Notice
indicates
This
product
BCAPRPP50
120V, 60 hz
15 amps (min)
Intermittent
120V, 1 Phase
1/2
6.3 amps
40°F to 120°F
45
o
from vertical
14" x 12"
2"
2" NPT female
11"
7"
4"
"Cap Switch"
capacitive water sensor
18 gauge 3 Conductor
with plug
GENERAL SAGETY INFORMATION
1. Know the pump application,
limitations, and po ten tial hazards.
Do not use to pump
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in flammable
and/or explosive atmospheres. Use pump
only with liquids compatible with pump
component materials. Failure to follow
this warning can result in personal
injury and/or property damage.
2. Make certain that the power source
(electric motor) conforms to the
requirements of the equipment.
Disconnect power before
servicing. If the power dis -
con nect is out of sight, lock
in the open po si tion and tag it to
prevent unexpected application of
power. Failure to do so could result in
fatal electrical shock!
3. Release all pressure within the system
before ser vic ing any component.
4. Drain all liquids from the system
before servicing.
contains dielectric motor oil for motor
heat transfer. Care should be taken when
disposing of this oil. Do not use this
pump in ponds or fountains because the
motor oil can be harmful to aquatic life.
5. Secure the discharge line before
starting the pump. An unsecured
discharge line will whip, possibly
Construction
Motor housing.......Cast iron
Volute ....................Cast iron
Impeller...................Glass reinforced PBT
Seal plate ...............Cast Iron
Shaft seal ...............Mechanical
Performance
GALLONS PER HOUR AT TOTAL
HEAD IN FEET
0
5
10
5700
4560
3240
331303-002 1/08
This
pump
15
900

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Blue Angel BRPP50T

  • Página 1 Warning The BRPP50T pump includes a wide angle Do not use to pump indicates float switch that turns the pump on and...
  • Página 2: General Safety Information

    Operating Instructions General Safety 16. Do not handle a pump or pump motor Grounding with wet hands or when standing on a Blade Information (Continued) wet or damp surface, or in water. 17. Do not hang this product by the causing personal injury and/or carry handle.
  • Página 3 6. For the BRPP50T, clean all dirt and 3-1/4 inches and should not be used in to repair this unit. Improper repair can deposits from the pump float.
  • Página 4 Operating Instructions Troubleshooting Chart - BRPP50T Symptom Possible Cause(s) Corrective Action Pump will not start or 1. Water level too low 1. Pump switch will not turn on unless water covers top of pump 2. Blown fuse or tripped circuit 2.
  • Página 5 Models BRPP50T and BCAPRPP50 Troubleshooting Chart - BCAPRPP50 Symptom Possible Cause(s) Corrective Action Pump will not start or 1. Water level too low 1. “Cap Switch” water sensor will not turn pump on unless water is within 1 inch of the top of the sensor.
  • Página 6 Limited Warranty For one (1) year on BRPP50T and two (2) years on BCAPRPP50, from the date of purchase, Blue Angel™ Pumps ("Blue angel") will repair or re place, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue angel to be defective in materials or work man ship.
  • Página 7 SÉCURITÉ et pour ÉVITER LES La BRPP50T pompe inclut un interrupteur PROBLÈMES D’ÉQUIPEMENT. à flotteur à angle large qui met la pompe Ce produit ou son cordon peuvent Rechercher les symboles suivants en marche et l’arrête tandis que le niveau...
  • Página 8 Instructions d’Utilisation Généralités sur la Remp 8. Fournir un système de dégagement lacer les de pression pour les pompes avec Sécurité (Suite) prises à deux broches avec des prises à lignes de décharge qui peuvent trois broches mises à la terre devenir obstruées ou coupées.
  • Página 9 Modéles BRPP50T et BCAPRPP50 Généralités sur la selon les exigences des codes locaux déranger la tuyauterie. et de la Province. Cette vanne permet 6. Cette BRPP50T pompe a un Sécurité (Suite) l’enlevage de la pompe et/ou du interrupteur à longe détachable avec clapet pour l’entretien.
  • Página 10 6. Pour le BRPP50T, nettoyer toute modèle. La réparation incorrecte peut saleté et dépôts du flotteur de la 7. Quand on utilise un interrupteur causer un danger de choc électrique.
  • Página 11: Guide De Dépannage - Brpp50T

    Modéles BRPP50T et BCAPRPP50 Guide de Dépannage - BRPP50T Symptôme Cause(s) Possible(s) Mesure Corrective La pompe ne se 1. Niveau d’eau trop bas 1. L’interrupteur de la pompe ne se met pas en marche sans démarre pas et ne que l’eau recouvre le haut de la pompe fonctionne pas 2.
  • Página 12: Guide De Dépannage- Bcaprpp50

    Instructions d’Utilisation Guide de Dépannage- BCAPRPP50 Symptôme Cause(s) Possible(s) Mesure Corrective La pompe ne se démarre 1. Niveau d’eau trop bas 1. Le capteur d’eau «Cap Switch » ne mettra pas la pompe en marche à moins que l’eau ne soit à 2,5 cm (1 po) du dessus pas et ne fonctionne pas du capteur.
  • Página 13: Garantie Limitée

    Garantie Limitée Pour un (1) an pour le BRPP50T et deux (2) ans pour le BCAPRPP50 à compter de la date d’achat, Blue Angel™ Pumps (« Blue angel ») réparera ou remplacera, à son choix, pour l’acheteur original, toute pièce(s) de sa Pompe de puisard ou Pompe à...
  • Página 14: Bomba De Aguas Negras De Hierro Fundido De 1/2 Hp

    2 pulgadas (5 cm). Ésto le dañados, devuelva la unidad al lugar indica que La BRPP50T bomba incluye un hay una situación que PODRIA donde la compró para que le sea interruptor de flotador de ángulo amplio ocasionarle la muerte o heridas de reemplazada.
  • Página 15 Modelos BRPP50T y BCAPRPP50 Informaciones Generales 5. Asegure la línea de descarga antes de de Seguridad (Continuación) encender la bomba. De lo contrario, ¡Peligro de choque eléctrico! ésta se enrollará y podría ocasionarle Nunca conecte los cables INFORMACIONES GENERALES DE verdes o verde con rayas heridas o daños a su propiedad.
  • Página 16: Instalación

    Pileta Estas bombas deben estar firmemente instaladas sobre sus patas y conectadas a una tubería rígida. Figura 3A- Piletas Prefabricadas (BRPP50T) Ésto evita que se mueva y se dañe durante el uso . 18. No use cordones de extensión. Válvula de chequeo 45 No camine en un área húmeda...
  • Página 17: Mantenimiento

    De lo contrario podría de tocar la unidad. ocasionar peligro de electrocutamiento. Si va a usar un diferencial diferente al 6. Para el modelo BRPP50T, limpie toda Esta fijado de fábrica, cerciórese de que la suciedad y depósitos del flotador de bomba cuando la bomba se apague todavía...
  • Página 18: Diagnóstico De Averías - Brpp50T

    Manual de Instrucciones Diagnóstico de Averías - BRPP50T Problema Posible(s) Causa(s) Acción a Tomar 1. El nivel de agua es muy bajo 1. El interruptor no encenderá la bomba a menos que la La bomba no se enciende o funciona bomba esté...
  • Página 19: Diagnóstico De Averías - Bcaprpp50

    Modelos BRPP50T y BCAPRPP50 Diagnóstico de Averías - BCAPRPP50 Symptôme Cause(s) Possible(s) Mesure Corrective La bomba no se 1. El nivel de agua es muy bajo 1. El dispositivo “Cap Switch” no enciende la bomba si el agua no enciende o funciona ha llegado a menos de 1 pulgada del tope del sensor.
  • Página 20: Garantía Limitada

    Manual de Instrucciones Garantía Limitada Durante un (1) año para BRPP50T y dos (2) años para BCAPRPP50, Blue Angel™ Pumps (“Blue angel”) reparará o reemplazará, según lo decida, para el comprador original, cualquier pieza o piezas de sus Bombas para cloacas o Bombas de agua (“Producto”) que después de un examen sea(n) hallada(s) por Blue angel como defectuosa(s) en su...

Este manual también es adecuado para:

Bcaprpp50

Tabla de contenido