CONTROLS
Your Pridiom dehumidifier features a microprocessor based digital control
system for optimal performance control.
All functions are accessible via the membrane keypad shown below:
Humidity &
Humidity
Setting
Humidity
Temperature
Display
Adjust
Display
Fan Speed
Select
Functions:
ON/OFF
The unit is switched on and off by pressing the 'ON/OFF' button. When the
unit is on, the fan runs in the set speed.
Humidity
Press the 'HUMIDITY ADJUST' buttons repeatedly to choose the desired level
of relative humidity in the area. The corresponding control lights will indicate
the selected percentage. The 'CONT' control light indicates that the unit is
running continuously, disregarding the relative humidity level in the area.
Note: When the desired level of humidity is achieved the compressor will stop
however, the fan will continue to run for approximately 15 minutes, this will
clear the heat exchanger of all collected water.
Fan speed
Press the 'FAN SPEED SELECT' button to select low or high speed. The cor-
responding control light will indicate this, Lo=low or Hi=high.
Humidity / Temperature display
The digital display will normally show the measured relative humidity in the
area.
Temperature
Timer
Display
On/Off
Select
Select
Set
Fan Speed
Display
8
Timer
Press the 'TIMER' button to run the unit for a limited time period only. The
selected time period (in hours) is displayed temporarily on the display panel,
repeatedly pressing the button cycles through the available settings. When
this mode is selected, the unit will switch itself off after the selected time pe-
riod has elapsed.
Temp
Press the 'TEMP' button to temporarily display the room temperature on the
display panel.
IMPORTANT:
This dehumidifier should not be used in temperatures below 45°F or above
95°F.
Defrost Control
The dehumidifier is equipped with an automatic de-icing mode to defrost
the refrigeration coil during low temperature operation. The compressor is
switched off whilst the fan continues to run.
ATTENTION:
This unit has an automatic compressor protection function.
If the unit is re-started within 3 minutes of switching off, it will run in
auto-protection-mode until 3 minutes has elapsed. During this time,
the compressor will not start and the unit will operate only with low
speed fan.
After this delay, the unit will resume operation at the previous settings.
TROUBLE SHOOTING
If the dehumidifier does not operate:
Make sure the unit is plugged in.
Ensure the humidistat control is turned on.
If the unit is noisy:
Make sure the dehumidifier is standing solidly and level.
If the unit is leaking:
Check the drainage tube for correct fitting.
Check for twists and bends in the drainage tube.
Check the drainage tube for a sufficient and continuous downward slope.
Check and make sure that the outlet of the drainage pipe is not under the
water level in the drain.
For warranty information or support contact Pridiom Technical Services
at 855-774-3466