STYLUS REMOVAL AND REPLACEMENT
Replace the stylus as shown above. Always hold
the stylus only by the plastic grip, take care not to
touch or damage the diamond tip or cantilever. Do
not force.
1.
Make certain cartridge is correctly mounted in tone arm and stylus is properly inserted in
cartridge.
2.
Protect stylus with stylus guard when dusting turntable.
3.
Regulate tone arm set–down to prevent stylus from striking edge of turntable or record.
4.
Do not handle tone arm while record is being played. Use cuing device if possible.
5.
If manual set-down is necessary, release arm as soon as stylus engages groove.
6.
Do not activate arm without record on turntable.
7.
Do not use damaged records.
8.
Check tracking force and anti-skating adjustments periodically
A Shure replacement stylus will restore your Shure cartridge to its originally specified performance level.
We strongly advise against the use of non-Shure styli with our cartridges. Such imitations will not perform
as well as a stylus designed specifically for your Shure cartridge. Such imitations may also cause permanent
damage to your records – severe mistracking can ruin a record in a single play.
SPolished, natural diamond
Stylus Tip:
SSpherical 18 µ (0.0007 in.) radius
Channel Balance:
Stylus
Stylus
Grip Color
N44–7
White
N44G
Gray
PATENT NOTICE: Manufactured under one or more of the following U.S. Patents: 4,275,888; 4,441,177;
4,473,897; 4,489,442.
Shure Incorporated ("Shure"), 222 Hartrey Avenue, Evanston, lllinois 60202–3696, warrants to the owner
of this product that it will be free in normal use, of any defects in workmanship and materials for a period of
one year from date of purchase. You should retain proof of date of purchase. Shure is not liable for any conse-
quential damages. If this Shure product has any defects as described above, carefully repack the unit, have
it insured, and return it prepaid to: Shure Incorporated, Attention:Service Department, 222 Hartrey Avenue,
Evanston, lllinois 60202 – 3696. If you are not in the United States, return the unit to your dealer or Authorized
Service Center for repair. The unit will be repaired or replaced and returned to you promptly, and if it cannot
be repaired or replaced, you may elect to receive a refund. This warranty does not include stylus wear.
2001, Shure Incorporated
27A3069 (AH)
TO PRESERVE STYLUS LIFE
USE ONLY SHURE REPLACEMENT STYLI
PRODUCT SPECIFICATIONS
Within 2 dB
Stereo Output (1
kHz
at 5 cm/sec peak
recorded velocity)
9.5 mV
20 to 20,000 Hz
6.2 mV
20 to 20,000 Hz
WARRANTY
Use soft brush with alcohol or an alcohol-distilled
water solution. Brush only from back to front as
shown. commercial cleaning solutions may
cause stylus damage.
Channel Separation:
Frequency
Channel
Response
Separation
20 dB at 1 kHz
20 dB at 1 kHz
Models N44-7, N44G
Replacement Styli
20 dB at 1 kHz
Recommended
tracking force
(in grams)
Max.
1.5 g
0.75 g
Printed in Mexico
Min.
3 g
1.5 g