1) PRODUCT CHARACTERISTICS
The XO 006A coding keypad is designed to control and protect
the entrances and exits of your dwelling:
- Code function: ENTERING WITH A CODE
- Alarm function: the system is self-protected by an integrated
alarm.
- Bell function: wired link to the bell of the dwelling.
The X0006A keypad is also used to control the entrance and
exit of people into and out of your dwelling:
- Electric opener / lock function
- Function: open automated gate system.
- Possible link with an additional exit button.
2) DESCRIPTION OF THE ELEMENTS
RED LED
BELL BUTTON
3) USING THE ELEMENTS
STATUS
NORM. MODE
OPEN LOCK/AUT
PROG.MOD.
CODE ENTRY
ALARM TRIGGERED
PASSWORD ERROR
PROG. ALARM
4) PROGRAMMING &
DEPROGRAMMING THE CODES
A- To enter programming mode:
1) Enter the default programming code . 6 6 6 8 8 8 8 .
2) Press # for 3 seconds .
B- To enter a new programming code:
1) Enter programming mode.
2) Press 1 .
3) Enter the new code of between 7 and 10 figures.
(Exemple : 1 2 3 4 5 6 7 8 )
4) Press # (to confirm).
5) If you want to continue the programming, move on directly to
another step. If you want to stop the programming, press
C- To add a new badge associated with a new user code
1) Enter programming mode.
2) Enter 2 .
4) Enter the new 6-figure code. (example:
5) Presse # (to confirm).
6) If you want to continue the programming, move on directly to
another
step. If you want to stop the programming, press
• Power supply: 12 V / 1 A.
• Alarm consumption: 50 mA.
• Temperatures allowed: -10°C ~ 70°C.
• Storage: max. of 600 codes
• Wire cross-section (keypad/lock): 1 mm²
RED LED
/Second
+ STOP
RAPID
+ STOP
ENGLISH
GREEN LED
CONFIRMATION BUTTON
GREEN LED
RAPID
RAPID
RAPID
• BEEP =
• FLASHING =
1 2 3 4 5 6 )
0 .
AUDIBLE BEEP
LONG
LONG
LONG
SUCCESSIVE
SHORT
0 .