Installation Instructions; Technical Features - O&O BSX/B Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The electronic unit O&O, models BSX/B and BSX/BL, for the automation of up-and-over doors and main doors, complies with the EEC directives
73/23 (Low Voltage) and 89/336 (EMC) and allows installation in observance of the current safety rules and regulations.
Complete for functioning (semiautomatic, automatic and hold to run control) and adjustment (working time, pause time and motor power) ranges.
Flexible for the choice of options (pre-flashing, flash light output controlled directly by the control unit, output for a courtesy light).
Safe in that it combines motor power adjustment and the output for the safety device with the reverser function.
Easy to install thanks to the control LEDs, pull out terminals and to the serigraphy on the printed circuit.
SUPPLY VOLTAGE:
MOTOR OUTPUT:
ACCESSORIES POWER OUTPUT:
FLAShING LIGhT OUTPUT:
"USER" OUTPUT FOR ThE COURTESY LIGhT:
WORKING TIME:
1) Install a 10Amp RCD or circuit breaker upstream from the installation. The switch must have, for the poles, a minimum 3 mm opening distance between the contacts.
2) Fix the container in an upright position and make sure that, when installation has been completed, the initial protection level IP54 is complied with (BSx/B model).
3) Differentiate and separate the "power" cables (minimum cross section of 1.5 mm2) from the signalling ones (minimum cross section of 0.5 mm2).
4) Short circuit the NC inputs (STOP, PhOTO, FCC, FCA) not being used.
5) Arrange in series any contacts connected to the same N.C. input.
6) Arrange in parallel all the contacts connected to the START input (N.O.).
7) Make the connections as described below, using the serigraphy on the printed circuit to help you.
P
POWER LINE
230V
40
Input with internal protection (5x20 5A fuse)
N
50Hz
2
COURTESY LIGHT
Output active during movement and for a further 60
230V~
44
USER
seconds after each stop.
45
200Wmax
MOTOR
4
230V~
4 - Open; 5 - Common; 6 - Close
M
5
~
Connect the capacitor to terminals 4-6
500VA max
6
N.B. Swap connections on terminals 4-6 to reverse
direction
FLASHING LIGHT
N
11
230V~
See DIP4 and DIP6 for the functioning of this
output.
12
P
80Wmax
GND
24 V - OUTPUT
24V~
14
For powering the accessories
15
5Wmax
(Photocells, receiver, etc.)
24 VAC
Internal protection (5x20 500 mA fuse)
BSX/B - BSX/BL

Installation instructions

GENERAL

TECHNICAL FEATURES

230 V ~ 50 Hz
230 V ~ / 500 W Max.
24 Vac / 200 mA Max.
230 V ~ / 80 W Max.
230 V ~ / 200W Max.
4"÷90"
INSTALLATON
CONNECTIONS
- 4 -
PAUSE TIME:
POWER ADJUSTMENT:
WORKING TEMPERATURE:
IP NUMBER:
MAxIMUM OVERALL DIMENSIONS (mm):
green
REVERSER (see NOTE and DIP5)
30
white
white
30 = +6Vdc
31
brown
brown
31 = signal input
32
3x0,5mm
2
32 = GND
10 ÷12m max.
PHOTOCELL
PhOTO
19
It works only during closing, stopping movement and
N.C.
E
reopening.
8
GND
START
START
9
See DIP3 for the functioning of this input
N.O.
E
8
GND
STOP
STOP
7
Using this push button/contact, all movement is stopped
N.C.
E
immediately and the automatic reclosing function is
8
GND
excluded.
N.C.
FCA
LIMIT SWITCHES (see note)
20
Opening limit switch (FCA) 20-22
N.C.
FCC
21
Closing limit switch (FCC) 21-22
GND
22
N.B. Swap connections on terminals 21-22 to reverse
the limit switches
GB
4"÷110"
30÷98%
-15°÷ +60°
IP 54 (mod. BSX/B)
200x275x130 (mod. BSX/B)