Digital Air Cleaning System
Improve your indoor air quality with your new germguardian
System. Multiple levels of cleaning include a combination filter
that captures allergens, and Charcoal filter to remove odors. UV-C light
technology enhances germ-killing.
Pre-Filter*
Captures initial dust and allergen particles.
Charcoal Filter* (aka Activated Carbon)
Charcoal/Activated Carbon contributes to the control and prevention of the growth of
bacteria, germs and mold.
Pet Pure
Filter
TM
Pet Pure Treatment inhibits the growth of mold, mildew and odor-causing bacteria on the
surface of the filter.
uv-C Light
UV-C light technology works with Titanium Dioxide (TiO
airborne germs. TiO
is activated by the UV-C light to decompose remaining odor
2
molecules caused by smoking, cooking and pets.
*Pre-Filter and Charcoal Filter are combined into one layer that attaches to the Filter.
AIR CLEANING LAYERS
uv-C
bulb
Main unit
E-6
Air Cleaning
®
) to enhance the elimination of
2
Lock & Release
button
Combination
Filter C
Rear Cover
includes Pre,
with Air Inlet Grill
Charcoal & PetPure
T
M
uv-C
filters
Metal
Shield
INSTALLING/REMovING CoMbINATIoN FILTER
The Air Cleaner will beep for 30 seconds and the Filter reset light will flash continuously
indicating that is is time to replace your filter. Replace the filter according to directions
then insert pen tip into Filter Reset area on control panel to restart the system.
Depending on usage, filter will last approximately 6 months.
1. Turn off and unplug the unit.
2. Press the Lock & Release
Button and remove the
Rear Cover from the unit.
4. Before inserting new filter, connect two filter pieces
together. Be sure the white, pleated side of each
filter piece is facing the same direction, then slide
the plastic tabs together and lock filter pieces in
place. Your new combination filter is now ready to
be inserted into air purifier.
6. Reattach the Rear Cover of the unit and securely latch into place.
3. Remove the used
Combination Filter (Filter C)
and dispose of it in
the garbage.
5. Insert filter system into the unit.
Consult the arrow on the filter
for correct installation direction.
E-7