Pinnacle Remington Silent Drive REM-150T-SDR-O Manual Del Usuario E Instrucciones De Operación página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Ventilation:
- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Not For Indoor Use.
Indoor use permitted only for the temporary
heating of buildings under construction,
alteration or repair.
DANGER
LEAD TO DEATH!
- Refer to Safety Information on pages 1-2 for
information about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm) for
each 100,00 Btu/Hr. (29 kW) of heater output. Provide
a larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
REM-150T-SDR-O
5.3 ft.²
3760 cm²
Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved
fuel until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that
is at least 6 feet long and is a minimum of 14
AWG rating.
4. Press the power button to power on the
heater.
5. Select desired temperature using temperature
+/- buttons.
6. The heater will ignite once the temperature
setting is higher than the ambient
temperature in the space.
© 2018, Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
Operation
CARBON
MONOXIDE
POISONING MAY
REM-220T-SDR-O
6.5 ft.²
5990 cm²
TIP: If the heater does not ignite, the
thermostat may be set too low. Increase
the temperature to a higher setting until the
heater ignites.
TIP: If the heater does not ignite; press
SDR 220 Rating Label + Control Panel
power button to power off the heater,
check steps 1-3 above and press power
button to power ON the heater.
Model - Modelo
BTU/Hr - BTU/h
Stopping / Restarting Heater:
Fuel Consumption Gal./Hr.
Consumo de Combustible Gal./h
Fuel Tank Capacity Gal.
-
To stop the heater, move the power switch to
Capacidad del Depósito Gal.
Pump Pressure PSI - Presión de le Bomba
the "Off" position and unplug the power cord.
V~Hz/Amps - V~Hz/Amperes
Fuse - Fusible
-
To restart the heater; wait 10 seconds and
Phase - Fase
Type of Fuel
follow ignition steps.
Tipo de aceite combustible
Maximum Air Outlet Temp. °F
Adjusting the Pump Pressure:
Max. Temp. Del Aire De Salida °C
Minimum Distance From Combustibles:
Outlet: 8 ft. (250 cm) Sides / Top / Rear: 4 ft. (125 cm)
-
Remove the right side cover (4 screws).
Minimas Distancias de Separacion de Materiales
Combustibles:
Behind the panel, the pump will have a
Salida de Aire: 8 ft. (250 cm)
Lateral / Superior / Posterior: 4 ft. (125 cm)
brass set screw. Turn screw in quarter turn
See Operating Instructions and Troubleshooting on
increments.
Las instrucciones de Funcionamiento y soluciónes
de problemas se encuentran en el panel lateral.
-
Clockwise increases the pressure.
-
Counterclockwise decreases pressure.
© 2017 Pinnacle Climate Technologies, Inc.
www.masterindustrialproducts.com
°F
Figure 3
SilentDrive Forced Air Heater User's Manual
5
MH-220T-SDR
220,000
1.67
13
93
120V~60Hz / 3.15
3.15A
No. 1 / Kerosene
No. 1 / Queroseno
1025
552
side panel.
COMPLIES WITH UL 733 AND
ANSIA 10.10-1998
CAN/CSA-B140.0-03 AND CSA B140.8-1967
Made In China
Hecho en China
°F
MASB-004

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Remington silent drive rem-220t-sdr-o

Tabla de contenido