40135
Preliminary procedures
• The electronic units are supplied with the Dip Switches set with ID = 1 (Master). In systems with a single panel, the ID must
be MASTER.
• If there are multiple panels in the system, a MASTER panel should be established and the others designated as SLAVE. In the
first electronic unit, leave dip-switches 1 and 2 set to OFF, while in the other electronic units dip-switches 1 and 2 should be
configured with reference to Tab. 1. Each electronic unit must have a single ID number.
When configuring the ID with a PC and the SaveProg programming software, the configuration will have priority over manual
configuration.
Buttons for manual configuration of parameters
Button PRG is used to confirm the selected data. Button P1 is used to proceed with the next phase of adjustment and after the last
adjustment, button P1 is used to exit configuration mode.
In the configuration phase, accessed by pressing and holding down button PRG, press and hold down button P1 too (approx-
imately 2s) until the electronic unit's speaker beeps. After accessing the configuration procedure, you can configure the parameters
given in the "Manual parameter configuration" chapter.
Manual parameter configuration
The order of the configurations shown in the manual sequence diagram is:
• Lock activation time adjustment
• Talk, self-start, response time adjustment.
• Button remapping (P1 and P2).
• EEPROM reset (clearing the set configurations and returning to the default data).
NOTE: Adjusting the talk, self-start and response time takes place in a single step.
For example, if the trimmer is set to 3, the value taken on will be talk = 50, self-start = 8, response = 12 seconds.
Tab. 4
COMMAND
POSITION
Lock
Talk
On
Response
Operation
• Buttons P1 or P2 send the calls to-
wards the indoor stations.
• If multiple electronic units have been
installed in a system and a call is sent
from one of these, if there is already
another electronic unit communicating
with an indoor station, the electronic
unit sending the call will emit a busy
tone.
NOTE:
P1 by default sends the call to the indoor
station identified with ID = 1
P2 by default sends the call to the indoor
station identified with ID = 2
10
Time configurable via "Activation time" trimmer using 16 positions
(time expressed in seconds)
1
2
3
4
5
6
1
2
4
6
8
10
30
40
50
60
70
80
5
6
8
10
11
13
7
10
12
15
17
20
Fig. 7
Figure 7 shows the connection to make between the electronic unit
and push button P2 housed in the printed circuit board which is locat-
ed in cover plate 13K1 together with the 3-conductor wiring.
7
8
9
10
11
12
12
14
16
18
20
22
90 100 110 120 130 140 150 160 170 180
15
16
18
20
21
23
22
25
27
30
32
35
PUSH BUTTON P2 CONNECTOR
PUSH BUTTON P2 CONNECTOR
EN
13
14
15
16
24
26
28
30
25
26
28
30
37
40
42
45
P1
P2