4
Installation
Important notes
4
Installation
4.1
Important notes
To ensure sufficient dissipation of heat, the device may only be attached
ƒ
to the control cabinet wall in a vertical position with the ventilation slots
at the top and bottom.
If a fanless variant is used, the rear housing plate must lie flat against the
ƒ
control cabinet wall to dissipate additional heat. The rear housing plate
can have a surface temperature of up to 65 °C.
(
Stop!
Short circuit and static discharge
The device contains components which are endangered in the case
of short circuit or static discharge.
Possible consequences:
ƒ
Protective measures:
ƒ
ƒ
ƒ
ƒ
ƒ
22
The device or parts of it will be destroyed.
Always switch off the voltage supply when working on the
device. This particularly applies:
– Before connecting / disconnecting connectors.
– Before plugging in / plugging out modules.
All persons handling printed circuit boards have to take account
of ESD measures.
Contacts of plug connectors must not be touched.
Printed circuit boards may be touched only at places free from
electrical contacts and may be placed only on appropriate
materials (e.g. on ESD packaging or conductive foam material).
Printed circuit boards may only be transported and stored in ESD
packaging.
l
MA_CPCx8xx DE/EN/FR/ES/IT 2.0