TROUBLE SHOOTING
FAULT
CAUSE
Unit does
No power to
not
machine.
operate
Fan is not
Obstructed air
turning
Outlet.
Unit
1. Insufficient
operating,
Dehumidifying
but room
time.
not dry
2. Poor air
circulation
in room.
3. Excessive
moisture in room.
1. Room air is dry.
Unit
2. Obstructed filter
collects
and coils
minimal
3.Room
water
temperature
is too low.
WARNING:
DO NOT attempt to rectify issues with unqualified
personnel.
If the problem you are experiencing is not listed
here, contact Global Industrial Customer Service.
SOLUTION
Plug in unit; check
power at outlet and
at base of unit.
Confirm power is
on.
Remove
obstruction.
1. Allow more time
for drying.
2. Increase air
circulation with fans.
3. Reduce external
air infiltration into
the room.
1. Check humidity
with hygrometer.
2. Check filter and
coils. Clean as
necessary.
3. Increase room
temperature.
- 4 -
TROUBLE SHOOTING
CODE
ER1
Error
Coil sensor
message
error
Display
Flashes every
Reading
one second
1. The coil
sensor terminals
are not securely
Reason
plugged in.
2. The coil
sensor is
damaged.
3. If unsolved,
there may be a
display panel
PCB issue.
1. Verify coil
sensor terminal
is securely
Remedy
plugged in.
2. Replace the
coil sensor.
3. Replace
display panel
PCB
NOTE:
The table above shows error messages that the system may
detect. If the display shows an "ER" message,
Unplug the unit and reinsert. This may reset the electronics, and
if issue is resolved, no further action is required.
If error message reappears, complete the following
troubleshooting steps under "Explanation." If this still does not
rectify the issue, contact Global Industrial customer service at
1-800-645-2986.
ER2
ER4
Humidity
Water pump
sensor error
fault or
blockage
Flashes every
Flashes
one second
every one
second
1. The humidity
sensor
Water is not
terminals are
draining from
not securely
the pump
plugged in.
reservoir or
2. The humidity
there is a
sensor fault.
lack of power
3. If is unsolved,
to the water
It may be
pump.
display panel
PCB issue
question.
1. Verify
1. Make sure
humidity sensor
maximum lift
terminal
is not
securely
exceeded.
plugged in.
End of hose
2. Replace the
should not
humidity sensor.
be higher
3.Replace
than 10ft.
display panel
above unit.
PCB
2. Check
pump for
debris or
blockage.