MAXIMUM TEMPERATURE SETTINGS
WARNING
The following table provides maximum temperature for common materials. The user is
responsible for determining the maximum temperature for materials included and not included on
this list. The heater setting should never exceed the maximum temperature of the material being
heated.
Material
ABS, CPVC, PE, PEX, PVC
Copper
MAINTENANCE INSTRUCTIONS
Anyone who reads and understands these instructions
is qualified to maintain this heater.
Maintenance:
All maintenance should be performed after the heater has cooled to room temperature and
with the electricity disconnected.
This product should be inspected prior to being installed and at least every 3 months during
use.
Dirt, oil, grease or other foreign matter can be removed with a damp rag and mild household
cleaners.
Do not attempt to repair a damaged heater.
Inspection:
Inspection should be performed after the heater has cooled to room temperature and with
the electricity disconnected.
The time percentage controller should be free of any cracks and the dial should be securely
attached.
The heating element should be free of any cuts, cracks, or punctures.
The power leads should not have any visible breaks in their insulation.
The heater should be free of any build-up of dirt, oil, grease, or other foreign matter.
Storage:
This product should be stored at room temperature in an environment with less than 80%
relative humidity.
Disposal:
This product does not contain any hazardous substances and may be discarded with
domestic waste.
®
© BriskHeat
Corporation. All rights reserved.
®
XtremeFLEX
HSTAT and MSTAT
Silicone Rubber Heating Tape
Maximum Temperature
140°F (60°C)
250°F (121°C)
7
EMERGENCY PROCEDURES
Read and understand these procedures prior to using this heater.
Disconnect power to the heater in the event of an emergency.
Electric Shock:
Do not touch the injured person while they are still in contact with the electrical current.
Call your local emergency service if the injured person experiences: severe burns,
confusion, difficulty breathing, heart rhythm problems, cardiac arrest, muscle pain and
contractions, seizures or a loss of consciousness.
Minor Burns:
Hold the burned area under cool running water for 10-15 minutes.
Remove rings or other tight items from burned area.
Major Burns:
Call your local emergency service.
Protect the person from further harm.
Remove rings or other tight items from burned area.
Monitor breathing and perform CPR if necessary.
Fire:
Call your local emergency service.
If it is safe to do so, use a fire extinguisher to fight the fire, otherwise evacuate to a safe
distance and wait for help to arrive.
This heater is built from material that will not support a flame but could ignite nearby
combustible material.
TROUBLESHOOTING GUIDE
Please read this guide prior to contacting BriskHeat
most commonly asked questions. If you are unable to identify the problem or need additional
assistance, please contact your local distributor/representative or the BriskHeat factory at:
1-800-848-7673, 614-294-3376, or bhtsales1@briskheat.com.
PROBLEM
SOLUTION(S)
Heater does not turn
Verify heater is connected to proper voltage.
on.
Verify controller is not in the "off" position.
Circuit breaker or
Varify circuit breaker is rated for the current requirements marked on
GFCI is tripping.
the heater's label.
Inspect heater for damage (see inspection procedure)
Inspect wiring terminations (qualified person only).
®
© BriskHeat
Corporation. All rights reserved.
®
XtremeFLEX
HSTAT and MSTAT
Silicone Rubber Heating Tape
®
. This guide is designed to answer the