Folding the Frame
WARNING! Do not fold crane while loaded.
1.
Lower Crane all the way.
2.
Remove R-Pins from the front Ring Pins.
Remove the front Ring Pins.
Leave rear Ring Pins in.
Bleeding Instructions
IMPORTANT! Before first use, check for proper
hydraulic oil level and thoroughly test the
equipment. If it does not work properly, bleed
excess air from its hydraulic system as follows:
1.
Open Release Valve and
lower Jack completely.
2.
Remove Oil Plug and fill with hydraulic
oil (sold separately) to full level.
3.
Apply downward pressure to the Boom and
Pump the Jack Handle quickly several times.
Item 60388
For technical questions, please call 1-888-866-5797.
3.
Raise Leg until it rests against Handle.
4.
Insert a front Ring Pin into the middle hole of
the Base, for each Leg, and reinsert R-Pins.
Note: Be certain that, when unfolding,
both Ring Pins and R-Pins are placed
back in the proper places.
4.
Check the Oil Fill Hole and, if necessary,
top off the Oil Fill Hole with hydraulic oil.
5.
Replace the Oil Plug and close
the Release Valve.
6.
Test the equipment several times for proper
operation before attempting to lift a load.
If, after bleeding, the equipment still does
not appear to be working properly, do
not use the equipment until it has been
repaired by a qualified service technician.
Page 9