Promaker PRO-CP24 Manual De Usuario página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Clean crank case and renew lubricating oil after the first 10 working hours.
3. Check the oil level after every 20 working hours, and replenish if
necessary (Fig.5).
4. Clean crank case and renew the oil, clean air filter every three months.
5. Open the drain cock under the tank to exhaust the condensate after
every 60 working hours but less than every 7 days.
6. Check the safety valve and pressure gauge by professional
organization every 6 months
and make sure they are in
correct condition.
7. Make sure there is no rust on
the air tank and the air tank is
not damaged.
8. Check the thickness of
the air tank by professional
organization every year and
make sure the thickness is not
less than 2.1mm.
Troubles and remedies
Trouble
Motor unable
running. running
too slow, or
getting hot
Sticking of
main
compressor
Terrible shake
or abnormal
noise
Possibles causes
a) Fault in line, or voltage insufficient
b) Power wire too thin or too long
c) Fault in pressure switch
d) Fault in motor
e) Sticking of main compressor
a) Moving parts burnt due to the oil
insufficient
b) Moving parts damaged, or stuck by
foreign body
a) Connecting part loosed
b) Foreign body got into main compressor
c) Piston knocking valve seat
d) Moving parts seriously worn
Fig. 5
Remedies
a) Check the line
b) Replace the wire
c) Repair or replace
d) Repair or replace
e) Check and repair
Check crankshaft,
bearing, connecting
rod, piston, piston ring,
etc. and replace if
necessary
a) Check and retighten
b) Check and clean
away
c) Replace with thicker
paper gasket
d) Repair or replace
5