Vacfomat V9
7. Operation
Turn on the main switch (2) on the left
side of the device housing. This acti-
vates the indicator light (5c) as well
as the display (4) on the front side. If
a new device has been delivered, the
7.1. Setting the heating time
Any time between 0:05 min. and
4:00 min. can be set by turning the
rotary/push button (3). The setting
is made in steps of five (5) sec. When
setting a new heating time, the infor-
mation shown on the display flashes
and must be confirmed before using
Material / Times
Heating min:sec
Biolon 0.5 mm
1:35
Biolon 0.625 mm
1:35
Biolon 0.75 mm
1:40
Biolon 1.0 mm
1:45
To ensure that the speci-
fied heating times of the
respective foils also provide
an adequate plasticisation
degree for good forming, the device
7.2. Preparatory measures
The cartridge holder (9) can be moved
between two positions by means of the
30
30
display will show 0:00. Otherwise, the
heating time which was used last will
be called up. An acoustic signal shows
that the device is ready for operation.
the device by pressing the rotary/push
button (3). For the optimum values
for the Dreve aligner thermoforming
programme, please refer to the table
below or the information printed on
the foil packaging.
Cooling min:sec
1:10
1:20
1:20
1:20
must be pre-heated every morning or
after a longer time out of use for at
least 0:30 min. without a foil.
lateral operating levers (6).
Heating position (A)
• Remove the foil cartridge (8) from the
device in lever position A by using the
handle to pull it forwards out of the
cartridge holder (9) and placing it on
• Bring the cartridge holder (9) into
a free table surface.
• Lower the cartridge holder (9) to
position B by means of the operat-
ing lever (6) and position the models
to be thermoformed on the model
support (7) into the slightly lowered
suction plates (18).
Tip:
The aligner models should not exceed
a max. height of 19 mm. The best
forming results can be achieved if you
align the models with the anterior teeth
towards the centre of the model sup-
port (7).
• Open the lid of the foil cartridge (8)
at the handle and insert the Biolon
foil into the bottom part with the
insulating layer facing downwards.
To safely fix the thermoforming foils,
retaining pins are installed in each
corner of the foil cartridge (8). The
Forming position (B)
V9 foils have corresponding holes in
the same positions. Slide the foil over
the retaining pins and close the lid.
position A until you notice that the
fixing magnets (19) have engaged
and push the foil cartridge (8) back
into the device until the stop has
been reached.
31