Testing the reader
1. Power up the reader. Verify the power-on self
test LED/beep sequence:
- green LED flashes; two short beeps
- yellow LED flashes; three short beeps
- red LED flashes
- yellow LED flashes
2. Verify the yellow LED is on continuously
indicating the reader is ready.
3. Present a badge that has been properly
enrolled in the system. Verify the green LED
lights and a short beep is heard.
Removing the cover
To remove the cover, squeeze the sides of the top
cover and pull to release the cover.
Specifications
Colors
Black, Charcoal, Gray
Power supply
Linear DC recommended
Voltage range
5 - 16 VDC
Temperature
-31°F to 149°F
a
range
(-35°C to 65°C)
Cable distance to
200 ft. (60.96 m) max.
b
panel
300 ft. (91.44 m) max.
500 ft. (152.4 m) max.
c
Read Range
- Mifare:
(Distances may
vary depending on
environment.)
- Vicinity: up to 3.5" (8.89 cm)
Wiegand output
- Mifare 4002 (40-bit)
- Vicinity 5502 (55-bit)
Regulatory
UL 294, CE, and FCC (part 15)
approvals and
standards
ISO Standards
Mifare ISO 14443A
Vicinity ISO 15693
UL evaluation for UL Listed Installations:
°
°
°
a. -25
F to 125
F (32
b. 500 ft. (152.4 m) max. @ 22 awg 12 VDC
200 ft. (60.96 m) max. @ 22 awg 5 VDC
c. Vicinity: up to 3.0" (7.62 cm)
@ 22 awg 12 VDC
@ 20 awg 12 VDC
@ 18 awg 12 VDC
up to 1.0" (2.54 cm)
Ultralight cards not supported
°
C to 52
C)
The voltage specification for this reader is 5-16
VDC, although 12 VDC or greater is recommended
for better performance and cable run distances.
The recommended cable gauge is 18-gauge to 22-
gauge. Check with the cable supplier to determine
the best choice for the application and installation
distance.
FCC compliance
The FCC requires the following statement: This
reader uses radio frequency energy, has been
tested, and complies with the limits of FCC testing.
Changes, modifications, or disregard of proper
installation and instructions not expressly approved
by UTC Fire & Security are strictly prohibited by the
FCC and could void the user's authority to operate
the equipment.
Ordering information
Product
T-200
(3 covers, 18" / 45.7 cm pigtail wire)
T-200
(3 covers, 84" / 214 cm pigtail wire)
Note: Each part number includes all three colors of the
cover plates (black, charcoal, gray).
Copyright © 2011, UTC Fire & Security.
All rights reserved.
The Transition Series product name and logo are
trademarks of UTC Fire & Security. Other trade names
used in this document may be trademarks or registered
trademarks of the manufacturers or vendors of the
respective products.
Document number: 460950002B - November 2011