AC Power
Data Stream 4 has an auto-ranging power supply that works with a voltage range
of 100–240 VAC, 50/60 Hz.
To eliminate wear and improve its lifespan, during periods of non-use
completely disconnect from power via breaker or by unplugging it.
Fuse Replacement 1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the fuse holder from its housing.
4. Remove the blown fuse from the clip on the front of the safety cap and
replace with a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.
Disconnect the product from power before replacing the fuse.
DMX Linking
The Data Stream 4 works with DMX controllers. For information
about
configuring
Data
Stream
4
for
additional
DMX
operation,
download
the
User
Manual
from
the
Chauvet
website:
http://www.chauvetlighting.com/product-manuals-literature/. For information about
DMX download the Chauvet DMX Primer, from the Chauvet website:
http://www.chauvetlighting.com/downloads/DMX_Primer_rev05_WO.pdf.
Mounting
Before mounting the Data Stream 4, read the
Safety Notes
in this QRG. The Data
Stream 4 conveniently mounts in a single rack space (1U). If mounting overhead,
make sure the mounting clamps (such as CLP-15 clamps from Chauvet) are
capable of supporting the weight of the product. Always use a mounting point and
at least one safety cable per product. For the Chauvet line of mounting clamps, go
to www.chauvetlighting.com/cables-clamps-main.html.
Mounting Clamp
(such as CLP-15 from Chauvet)
Rear View
Safety Cable
(such as CH-05 from Chauvet)
Overhead Mounting
Diagram
Bottom View
4